机器人辅助前列腺癌根治术中淋巴结放射引导手术的DROP-IN伽马探头
DROP-IN探头在体内识别了全部47枚前哨淋巴结(100%),荧光成像识别91%,传统腹腔镜探头仅识别76%,且未观察到相关不良事件。
要点
- DROP-IN探头在机器人手术中识别前哨淋巴结的体内检出率为100%。
- 传统腹腔镜伽马探头检出率仅76%,荧光成像为91%。
- DROP-IN探头使用未观察到相关不良事件,安全可行。
核心结论
- DROP-IN探头因操控性改善,前哨淋巴结检出率优于传统伽马探头和荧光成像,是机器人放射引导手术的有价值工具。
主要发现
- DROP-IN伽马探头在体内追踪的47枚前哨淋巴结中识别100%。
- 荧光成像识别其中91%的前哨淋巴结。
- 传统腹腔镜伽马探头仅识别76%的前哨淋巴结,检测不准确与特定解剖区域相关。
- 未观察到与DROP-IN探头使用相关的不良事件。
临床怎么用
- 在机器人辅助前列腺癌根治术中,可使用DROP-IN伽马探头进行前哨淋巴结的放射引导检测,并可结合荧光成像互补确认淋巴结位置。
局限性
- 单中心小样本研究,随访中位18个月,仍需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The DROP-IN gamma probe was introduced to overcome the restricted manoeuvrability of traditional laparoscopic gamma probes. Through enhanced manoeuvrability and surgical autonomy, the DROP-IN promotes the implementation of radioguided surgery in the robotic setting. OBJECTIVE: To confirm the utility and safety profile of the DROP-IN gamma probe and to perform a comparison with the traditional laparoscopic gamma probe and fluorescence guidance. DESIGN, SETTING, AND PARTICIPANTS: Twenty-five prostate cancer patients were scheduled for a robot-assisted sentinel lymph node (SN) procedure, extended pelvic lymph node dissection, and prostatectomy at a single European centre. SURGICAL PROCEDURE: After intraprostatic injection of indocyanine green (ICG)-99mTc-nanocolloid (n = 12) or 99mTc-nanocolloid + ICG (n = 13), SN locations were defined using preoperative imaging. Surgical excision of SNs was performed under image guidance using the DROP-IN gamma probe, the traditional laparoscopic gamma probe, and fluorescence imaging. MEASUREMENTS: Intraoperative SN detection was assessed for the different modalities and related to anatomical locations. Patient follow-up was included (a median of 18 mo). RESULTS AND LIMITATIONS: Overall, 47 SNs were pursued in vivo by the DROP-IN gamma probe, of which 100% were identified. No adverse events related to its use were observed. In vivo fluorescence imaging identified 91% of these SNs. The laparoscopic gamma probe identified only 76% of these SNs, where the detection inaccuracies appeared to be related to specific anatomical regions. CONCLUSIONS: Owing to improved manoeuvrability, the DROP-IN probe yielded improved SN detection rates compared with the traditional gamma probe and fluorescence imaging. These findings underline that the DROP-IN technology provides a valuable tool for radioguided surgery in the robotic setting. PATIENT SUMMARY: Radioguided robot-assisted surgery with the novel DROP-IN gamma probe is feasible and safe. It enables more efficient intraoperative identification of sentinel lymph nodes than can be achieved with a traditional laparoscopic gamma probe. The use of the DROP-IN probe in combination with fluorescence imaging allows for a complementary optical confirmation of node localisations.
引用
- Dell'Oglio P, Meershoek P, Maurer T, et al. A DROP-IN Gamma Probe for Robot-assisted Radioguided Surgery of Lymph Nodes During Radical Prostatectomy. Eur Urol. 2020. PMID: 33203549. doi:10.1016/j.eururo.2020.10.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。