膀胱影像报告和数据系统(VI-RADS)在前列腺癌中的前瞻性验证:下一代磁共振扫描仪及去噪深度学习重建的价值
这项前瞻性研究纳入98例膀胱癌疑似患者,最终分析68例病理确诊尿路上皮癌患者,评估VI-RADS预测肌层浸润的准确性。VI-RADS评分≥4诊断肌层浸润的准确率为94%(AUC 0.92)。联合去噪深度学习重建可显著提高T2加权成像的AUC并纠正部分误诊。
要点
- VI-RADS评分≥4诊断肌层浸润准确率94%(AUC 0.92)
- 去噪深度学习重建联合T2加权成像可提高诊断准确性
- 下一代磁共振扫描仪下VI-RADS对肌层浸润预测准确性高
核心结论
- 在下一代磁共振扫描仪的前瞻性验证中,VI-RADS对经尿道膀胱肿瘤电切术前膀胱癌患者肌层浸润具有高预测准确性。
- T2加权成像联合去噪深度学习重建可能进一步提高VI-RADS的诊断准确性。
研究设计与样本
- 前瞻性纳入98例在经尿道膀胱肿瘤电切术前接受膀胱多参数磁共振成像(使用下一代磁共振扫描仪)的患者。
- 最终分析68例病理确诊为尿路上皮膀胱癌的患者,根据VI-RADS对肿瘤分类,采用受试者工作特征曲线分析评估VI-RADS对肌层浸润的预测准确性。
主要发现
- 经尿道膀胱肿瘤电切标本中18例(26%)检测到肌层浸润。
- 基于受试者工作特征曲线分析,VI-RADS评分的最佳截断值为≥4。
- 使用VI-RADS≥4诊断肌层浸润的准确率为94%(AUC 0.92)。
- 联合去噪深度学习重建显著提高了T2加权成像分类的AUC。
- 最终VI-RADS评分误诊的4例患者中,有3例通过T2加权成像联合去噪深度学习重建得到正确诊断。
关键数值与推荐
- VI-RADS评分≥4被确定为预测肌层浸润的最佳截断值。
- VI-RADS≥4诊断肌层浸润的准确率为94%,AUC为0.92。
临床怎么用
- 对于拟行经尿道膀胱肿瘤电切术的膀胱癌患者,可采用VI-RADS评分≥4预测肌层浸润。
- 联合去噪深度学习重建与T2加权成像可能有助于提高VI-RADS诊断准确性,减少误诊。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The Vesical Imaging Reporting and Data System (VI-RADS) was launched in 2018 to standardize reporting of magnetic resonance imaging for bladder cancer. This study aimed to prospectively validate VI-RADS using a next-generation magnetic resonance imaging scanner and to investigate the usefulness of denoising deep learning reconstruction. MATERIALS AND METHODS: We prospectively enrolled 98 patients who underwent bladder multiparametric magnetic resonance imaging using a next-generation magnetic resonance imaging scanner before transurethral resection of bladder tumor. Tumors were categorized according to VI-RADS, and we ultimately analyzed 68 patients with pathologically confirmed urothelial bladder cancer. We used receiving operating characteristic curve analyses to assess the predictive accuracy of VI-RADS for muscle invasion. Sensitivity, specificity, positive/negative predictive value, accuracy and area under the curve were calculated for different VI-RADS score cutoffs. RESULTS: Muscle invasion was detected in the transurethral resection of bladder tumor specimens of 18 patients (26%). The optimal cutoff value of the VI-RADS score was determined as ≥4 based on the receiver operating curve analyses. The accuracy of diagnosing muscle invasion using a cutoff of VI-RADS ≥4 was 94% (AUC 0.92). Additionally, we assessed the utility of denoising deep learning reconstruction. Combination with denoising deep learning reconstruction significantly improved the AUC of category by T2-weighted imaging, and of the 4 patients who were misdiagnosed by the final VI-RADS score 3 were correctly diagnosed by T2-weighted imaging+denoising deep learning reconstruction. CONCLUSIONS: In this prospective validation study with a next-generation magnetic resonance imaging scanner, VI-RADS showed high predictive accuracy for muscle invasion in patients with bladder cancer before transurethral resection of bladder tumor. Combining T2-weighted imaging with denoising deep learning reconstruction might further improve the diagnostic accuracy of VI-RADS.
引用
- Taguchi S, Tambo M, Watanabe M, et al. Prospective Validation of Vesical Imaging-Reporting and Data System Using a Next-Generation Magnetic Resonance Imaging Scanner-Is Denoising Deep Learning Reconstruction Useful? J Urol. 2020. PMID: 33021428. doi:10.1097/JU.0000000000001373
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。