类比尿流图与尿流率检查在男性下尿路症状中的对应关系
本研究前瞻性纳入545名男性,最终358人符合标准,评估一种由4种尿流图像组成的视觉工具(ANUF)与尿流率参数的相关性。
要点
- ANUF与Qmax和Qave均呈显著负相关,图像序号越大对应Qmax越低。
- Image1至Image4的Qmax均值分别为20.4、15.5、13.5、10.4 mL/s,除Image1与Image2外两两差异显著。
- 线性回归模型给出各图像Qmax的95%CI,可供临床粗略对应。
核心结论
- ANUF是一种有用且廉价的工具,与Qmax相关,且每种图像对应一定的Qmax范围及其均值。
研究设计与样本
- 大学医院前瞻性研究,2018年9月至2019年1月共纳入545名男性,最终358人符合纳入标准。
- 收集年龄、尿流率图型、Qmax、平均流率、排尿量、残余尿及所选图像,采用Spearman秩检验、ANOVA、Tukey检验及线性回归模型分析。
主要发现
- 平均年龄64.6±12岁。
- Qmax均值±标准差:Image1为20.4±10.5 mL/s,Image2为15.5±6.4 mL/s,Image3为13.5±6.0 mL/s,Image4为10.4±5.4 mL/s。
- ANUF与Qmax呈负相关(r=-0.317;P<.0001),与Qave呈负相关(r=-0.305;P<.0001)。
- 线性回归模型计算的Qmax置信区间:Image1为17.8 mL/s,95%CI [14.9-21.5];Image2为14.3 mL/s,95%CI [13.0-15.7];Image3为12.3 mL/s,95%CI [11.5-13.1];Image4为9.1 mL/s,95%CI [8.1-10.3]。
临床怎么用
- 在无法进行尿流率检查时,可用ANUF图像粗略估计Qmax范围,辅助评估男性下尿路症状。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To study the correlation between a new visual tool (ANalogical UroFlowmetry (ANUF)) and uroflowmetry (UF) parameters when performed to assess male lower urinary tract symptoms (MLUTS). METHODS: We configured an original pictogram composed of 4 different urine streams. In the setting of a University Hospital based prospective study where 545 men were enrolled between September 2018 and January 2019. Variables collected were age, UF pattern, Qmax, average flow rate (Qave), voided volume, postvoid residual, and selected image. The Spearman's rank test, ANOVA, and Tukey test, as well as the lineal regression model were used. RESULTS: A total of 358 patients fulfilled the inclusion criteria. Mean age was 64.6 ± 12 years. Mean value and standard deviationfor the Qmax were 20.4 ± 10.5 mL/s for Image1; 15.5 ± 6.4 mL/s for Image2; 13.5 ± 6.0 mL/s for Image3 and 10.4 ± 5.4 mL/s for Image4. Statistically significant negative correlations were found between ANUF and Qmax (r = -0.317; P<.0001), and ANUF and Qave (r = -0.305; P<.0001). Qmax mean values among images were statistically different when compared in pairs, except Image1 and Image2 (P= .153). The confidence intervals calculated through the lineal regression model for the Qmax and each image were Image1) 17.8, confidence interval [CI] 95%: [14.9-21.5] mL/s; Image2) 14.3, CI 95%: [13.0-15.7] mL/s; Image3) 12.3, CI 95%: [11.5-13.1] mL/s and Image4) 9.1, CI 95%: [8.1-10.3] mL/s. CONCLUSION: According to our results, ANUF is a useful and inexpensive tool presenting a correlation with the Qmax as well a correspondence of each image with a range of Qmax and its mean value.
引用
- Rogel R, Lorenzo L, Avargues A, et al. ANalogical UroFlowmetry (ANUF): Correspondence Between This New Visual Pictogram and Uroflowmetry in Men With Lower Urinary Tract Symptoms: A new approach for the study of male micturition dynamics. Urology. 2020. PMID: 32866510. doi:10.1016/j.urology.2020.08.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。