多中心验证灌注式机器人辅助肾部分切除术手术模拟平台:采用临床相关客观模拟指标(CROMS)
本研究对高保真灌注式非活体机器人辅助肾部分切除术(RAPN)模拟平台进行多中心验证,基于4.2 cm上极肾肿瘤患者CT构建3D打印水凝胶肾脏模型。
要点
- 灌注式RAPN模拟平台在复制手术步骤、出血、组织质地和外观方面优于其他程序性模拟。
- 专家组console time、热缺血时间、估计失血量及GEARS评分均显著优于新手组(均P<0.001)。
- GEARS评分与CROMS指标高度相关,六例主要术中并发症仅见于新手模拟。
核心结论
- 该灌注式程序化模型提供了具有客观、临床相关且手术特异性性能指标的仿真模拟平台。
研究设计与样本
- 基于4.2 cm上极肾肿瘤(RENAL肾测量评分7×)患者CT扫描,利用3D打印和水凝胶铸造开发RAPN模型。
主要发现
- 专家评分显示模型在复制手术步骤、出血、组织质地和外观方面优于其他程序性模拟。
- CROMS指标组间差异显著:console time(P < 0.001)、热缺血时间(P < 0.001)、估计失血量(P < 0.001),GEARS评分(P < 0.001)。
- 六例主要术中并发症仅发生在新手模拟中,GEARS评分与CROMS高度相关。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To conduct a multi-institutional validation of a high-fidelity, perfused, inanimate, simulation platform for robot-assisted partial nephrectomy (RAPN) using incorporated clinically relevant objective metrics of simulation (CROMS), applying modern validity standards. MATERIALS AND METHODS: Using a combination of three-dimensional (3D) printing and hydrogel casting, a RAPN model was developed from the computed tomography scan of a patient with a 4.2-cm, upper-pole renal tumour (RENAL nephrometry score 7×). 3D-printed casts designed from the patient's imaging were used to fabricate and register hydrogel (polyvinyl alcohol) components of the kidney, including the vascular and pelvicalyceal systems. After mechanical and anatomical verification of the kidney phantom, it was surrounded by other relevant hydrogel organs and placed in a laparoscopic trainer. Twenty-seven novice and 16 expert urologists, categorized according to caseload, from five academic institutions completed the simulation. RESULTS: Clinically relevant objective metrics of simulators, operative complications, and objective performance ratings (Global Evaluative Assessment of Robotic Skills [GEARS]) were compared between groups using Wilcoxon rank-sum (continuous variables) and parametric chi-squared (categorical variables) tests. Pearson and point-biserial correlation coefficients were used to correlate GEARS scores to each CROMS variable. Post-simulation questionnaires were used to obtain subjective supplementation of realism ratings and training effectiveness. RESULTS: Expert ratings demonstrated the model's superiority to other procedural simulations in replicating procedural steps, bleeding, tissue texture and appearance. A significant difference between groups was demonstrated in CROMS [console time (P < 0.001), warm ischaemia time (P < 0.001), estimated blood loss (P < 0.001)] and GEARS (P < 0.001). Six major intra-operative complications occurred only in novice simulations. GEARS scores highly correlated with the CROMS. CONCLUSIONS: This perfused, procedural model offers an unprecedented realistic simulation platform, which incorporates objective, clinically relevant and procedure-specific performance metrics.
引用
- Ghazi A, Melnyk R, Hung AJ, et al. Multi-institutional validation of a perfused robot-assisted partial nephrectomy procedural simulation platform utilizing clinically relevant objective metrics of simulators (CROMS). BJU Int. 2020. PMID: 32936977. doi:10.1111/bju.15246
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。