机器人肾部分切除术中术中不良事件报告质量评估:29,227例的系统综述与累积分析
该系统综述检索2000年至2019年英文文献,评估机器人肾部分切除术中术中不良事件(IAE)的报告质量。共59项研究(35.3%)报告零IAE,108项(64.7%)报告至少1例IAE;报告与分级质量随时间未见改善。
要点
- 机器人肾部分切除术中IAE总体发生率为2.6%,术中出血最常见(58%)。
- 仅64.7%的研究报告了至少1例IAE,35.3%报告零IAE,报告标准不统一。
- IAE的报告与分级质量在2000至2019年间未见改善。
核心结论
- 机器人肾部分切除术中IAE报告缺乏标准化,报告与分级质量随时间未见改善,需更严格的报告规范。
研究设计与样本
- 遵循PRISMA指南的系统综述与累积分析,检索PubMed、Scopus和Web of Science数据库2000年1月1日至2019年1月1日的英文文献。
主要发现
- 59项研究(35.3%)报告零IAE,108项研究(64.7%)报告至少1例IAE。
- 术中出血是最常见的IAE,占58%。
- 分析显示IAE的报告与分级质量随时间未见改善。
关键数值与推荐
- EAU于2019年提出泌尿外科IAE标准化报告工具,但本文未列出具体推荐条款。
临床怎么用
- 临床应参照EAU标准化工具报告机器人肾部分切除术中IAE,尤其关注术中出血。
局限性
- 文献检索截止2019年1月1日,未纳入此后发表的研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The definition of intraoperative adverse events (IAEs) still lacks standardization, hampering the assessment of surgical performance in this regard. Over the years, efforts to address this issue have been carried out to improve the reporting of outcomes. In 2019, the European Association of Urology (EAU) proposed a standardized reporting tool for IAEs in urology. The objective of the present study is to distill systematically published data on IAEs in patients undergoing robotic partial nephrectomy (RPN) for renal masses to answer three key questions (KQs). (KQ1) Which system is used to report the IAEs? (KQ2) What is the frequency of IAEs? (KQ3) What types of IAEs are reported? A comprehensive systematic review of all English-language publications on RPN was carried out. We followed the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) guidelines to evaluate PubMed, Scopus, and Web of Science databases (from January 1, 2000 to January 1, 2019). Quality of reporting and grading complications were assessed according to the EAU recommendations. Globally, 59 (35.3%) and 108 (64.7%) studies reported zero and one or more IAEs, respectively. Overall, 761 (2.6%) patients reported at least one IAE. Intraoperative bleeding is reported as the most common IAE (58%). Our analysis showed no improvement in reporting and grading of IAEs over time. PATIENT SUMMARY: Up to now, an agreement regarding the definition and reporting of intraoperative adverse events (IAEs) in the literature has not been achieved. The aim of this study is to evaluate the reporting of IAEs in patients undergoing robotic partial nephrectomy (RPN) after a systematic review of the literature. More rigorous reporting of IAEs during RPN is needed to measure their impact on patients' perioperative care.
引用
- Cacciamani GE, Tafuri A, Iwata A, et al. Quality Assessment of Intraoperative Adverse Event Reporting During 29 227 Robotic Partial Nephrectomies: A Systematic Review and Cumulative Analysis. Eur Urol Oncol. 2020. PMID: 32474006. doi:10.1016/j.euo.2020.04.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。