文献速递泌尿系结石

硅胶水涂层双环输尿管支架对肾结石输尿管软镜术后症状与生活质量的影响:随机多中心临床研究

Effects of Silicone Hydrocoated Double Loop Ureteral Stent on Symptoms and Quality of Life in Patients Undergoing Flexible Ureteroscopy for Kidney Stone: A Randomized Multicenter Clinical Study.
PubMed 文献 · J Urol · 2020-05-05

该多中心单盲随机试验纳入141例肾结石行输尿管软镜患者,比较硅胶水涂层支架与Percuflex Plus支架。主要终点为D20拔管前USSQ躯体疼痛指数,硅胶组较对照组低25%(18.7 vs 25.1,p=0.015),D2、D7、D20泌尿症状评分也更低,不良事件无差异,推荐用于结石需置管患者。

要点

  • 硅胶水涂层支架在D20躯体疼痛评分较Percuflex Plus支架低25%(p=0.015)
  • 硅胶组D20泌尿症状评分显著更低(26.4 vs 31.8,p<0.001)
  • 两组不良事件与安全性无差异,推荐结石需置管患者使用硅胶支架

核心结论

  • 硅胶Imajin hydro支架较Percuflex Plus支架显著减少患者不适,推荐用于结石需置管患者。

研究设计与样本

  • 多中心、单盲、前瞻性随机试验,纳入141例因肾结石行输尿管软镜治疗的患者。

主要发现

  • D20拔管前USSQ躯体疼痛评分硅胶组18.7(11.4) vs 对照组25.1(14.2),低25%(p=0.015)。
  • D20泌尿症状评分硅胶组26.4(7.7) vs 对照组31.8(8.1)(p<0.001),D2和D7也较低。
  • 两组不良事件与安全性无差异,USSQ自问卷缺失或不完整回答有限。

关键数值与推荐

  • 主要终点为D20拔管前USSQ躯体疼痛指数,硅胶组较对照组低25%(p=0.015)。
  • D20 USSQ泌尿症状评分硅胶组26.4(7.7) vs 31.8(8.1)(p<0.001)。

临床怎么用

  • 对肾结石输尿管软镜术后需置管的患者,可优先选用硅胶水涂层双环支架以减轻疼痛和泌尿症状。

局限性

  • 试验完成率80.1%(113例),存在失访偏倚可能。
  • 单盲设计,患者主观评分可能受预期影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We compared the hydrocoated silicone stent (Coloplast Imajin® hydro) to Percuflex™ Plus stent (Boston Scientific) in terms of patient comfort and quality of life after flexible ureteroscopy for stone disease over a 5-week prospective followup. MATERIALS AND METHODS: This is a multicenter, single-blind, prospective, randomized trial of 141 patients treated with flexible ureteroscopy for renal stones. Primary outcome was Ureteral Stent Symptom Questionnaire (USSQ) Body Pain Index recorded before Double-J® stent removal at day (D) 20. Secondary endpoints were USSQ scores at intermediate dates (D2, D7, D20) and 2 weeks after stent withdrawal (D35), occurrence of adverse events and stent encrustation. RESULTS: The trial was completed by 113 (80.1%) patients. Mean (SD) USSQ body pain scores were 25% lower at D20 for the silicone stent at 18.7 (11.4) vs 25.1 (14.2) (p=0.015). No difference in terms of adverse events and safety profile was observed. USSQ urinary symptoms scores at D2, D7 and D20 were lower in the silicone stent group at 26.4 (7.7) vs 31.8 (8.1) at D20 (p <0.001). The use of USSQ self-questionnaires was associated with a limited number of missing or incomplete answers. CONCLUSIONS: The primary results of this large sample prospective randomized controlled study comparing the silicone Imajin hydro stents to the Percuflex Plus stent show that silicone stents are associated with significantly less patient discomfort. We would recommend their use in patients who require stenting for stone disease.

来源:J Urol,查看原文。版权归原作者所有。

引用

  1. Wiseman O, Ventimiglia E, Doizi S, et al. Effects of Silicone Hydrocoated Double Loop Ureteral Stent on Symptoms and Quality of Life in Patients Undergoing Flexible Ureteroscopy for Kidney Stone: A Randomized Multicenter Clinical Study. J Urol. 2020. PMID: 32364838. doi:10.1097/JU.0000000000001098

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。