文献速递前列腺增生与排尿功能障碍

国际尿失禁咨询问卷-满意度(ICIQ-S):泌尿外科术后满意度新患者报告结局指标的心理测量学测试

International Consultation on Incontinence Questionnaire-Satisfaction: psychometric testing of a new patient-reported outcome measure for the evaluation of satisfaction after urological surgery.
PubMed 文献 · BJU Int · 2020-05-20

本研究在410例因男性前列腺梗阻接受两种手术之一的患者中,评估新型患者报告结局指标ICIQ-S的心理测量学特性。结果显示,六个条目组成的评分域(Cronbach's α 0.89)及一个独立总体满意度条目(0-10分)具有良好的信效度,术后评分与症状减轻和生活质量改善相关。

要点

  • ICIQ-S包含6个手术结局相关条目(α=0.89)和1个总体满意度条目(0-10分)构成评分部分。
  • 术后ICIQ-S评分与ICIQ-Male LUTS、IPSS及ICIQ-LUTS QoL等已知效度PROMs相关,支持结构效度。
  • 缺失数据总体较低(平均1.6%,范围<1-3.1%),但“并发症”和“性生活满意度”条目缺失较高。

核心结论

  • ICIQ-S的六条目评分域及独立总体满意度条目具有良好的效度和信度,可用于评估泌尿外科手术满意度。

研究设计与样本

  • 在比较两种男性前列腺梗阻手术的随机对照试验中,于术后1.5、3和12个月使用发展版ICIQ-S(dICIQ-S)进行评估。
  • 共纳入410例男性患者;采用Cronbach's α评估信度,通过与同时施测的已知效度PROMs(ICIQ-Male LUTS、IPSS、ICIQ-LUTS QoL)的相关性评估结构效度。

主要发现

  • dICIQ-S缺失数据总体较低,平均(范围)为1.6%(<1-3.1%),但“并发症”条目缺失6.8%,“性生活满意度”条目缺失9.2%。
  • 所有条目均发现高度天花板效应。
  • 因子分析识别出六个与手术结局相关的条目(Cronbach's α 0.89),构成ICIQ-S的评分部分,并保留一个独立的总体满意度条目(0-10分)。
  • 另保留七个与体验和期望满意度相关的非评分条目。
  • 术后dICIQ-S评分与同时施测PROMs所测量的症状减轻和生活质量改善相关,符合假设。

关键数值与推荐

  • ICIQ-S评分部分由六个手术结局相关条目组成(Cronbach's α 0.89),另有一个独立的总体满意度条目,评分0-10分。
  • 七个非评分条目被保留,用于未来在不同患者人群中适配和进一步验证ICIQ-S。

临床怎么用

  • ICIQ-S可用于评估男性前列腺梗阻术后患者对手术结局的满意度,包含六个评分条目和一个总体满意度条目。
  • 非评分条目可用于临床访谈中了解患者对体验和期望的满意度,但尚未纳入评分。

局限性

  • 所有条目均存在高度天花板效应,可能限制其对高满意度人群的区分能力。
  • “并发症”和“性生活满意度”条目缺失数据较高(分别为6.8%和9.2%)。
  • 研究仅纳入接受前列腺梗阻手术的男性患者,外推至其他泌尿外科手术或人群需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate the psychometric properties of a new patient-reported outcome measure (PROM), the International Consultation on Incontinence Questionnaire-Satisfaction (ICIQ-S), to assess satisfaction after urological surgery. SUBJECTS/PATIENTS AND METHODS: Following item development, the developmental ICIQ-S (dICIQ-S) was used within in a randomised control trial comparing two types of surgery for male prostatic obstruction at 1.5, 3, and 12 months after surgery. Reliability was assessed by Cronbach's α and construct validity by the correlation of scores with concurrently administered PROMs of known validity: ICIQ-Male Lower Urinary Tract Symptoms (LUTS), International Prostate Symptom Score, and the ICIQ-LUTS Quality of Life. RESULTS: A total of 410 men were included in the trial. Missing data was generally low for the dICIQ-S [mean (range) 1.6 (<1-3.1)%] except for the items 'complications' 6.8% and 'satisfaction with sex-life' 9.2%. High ceiling effects were found in all items. Factor analysis identified six items related to surgical outcomes (Cronbach's α 0.89), which have formed the scored part of the ICIQ-S, together with a standalone overall satisfaction item, scored 0-10. Seven additional unscored items, related to satisfaction with experiences and expectations, were also retained. As hypothesised, post-surgery dICIQ-S scores were correlated with reduced symptoms and improved quality of life as measured by the concurrent PROMs. CONCLUSION: The results support the validity and reliability of a scored six-item domain for evaluating satisfaction with surgical outcomes, together with a standalone scored overall satisfaction item. The further unscored seven standalone items are anticipated to be used as the basis for adaptation and further validation of the ICIQ-S in different patient populations.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Uren AD, Cotterill N, Hashim H, et al. International Consultation on Incontinence Questionnaire-Satisfaction: psychometric testing of a new patient-reported outcome measure for the evaluation of satisfaction after urological surgery. BJU Int. 2020. PMID: 32320131. doi:10.1111/bju.15091

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。