三维增强现实机器人辅助肾部分切除术治疗复杂肿瘤(PADUA≥10):克服超声引导的新术中工具
该回顾性研究纳入91例复杂肾肿瘤(PADUA评分≥10)行机器人辅助肾部分切除术的患者,其中48例采用三维增强现实(3D AR)引导,43例采用二维超声(2D US)引导。结果显示3D AR组整体缺血率更低(45.8% vs 69.7%,p=0.03)、剜除率更高(62.5% vs 37.5%,p=0.02)、集合系统损伤率更低(10.4% vs 45.5%,p=0.003),且术后3个月肾扫描估算肾血浆流量下降更少(-12.38 vs -18.14,p=0.01)。
要点
- 3D AR引导可更准确识别肿瘤及肾内结构,降低整体缺血率。
- 3D AR组剜除率更高、集合系统损伤率更低。
- 3D AR组术后3个月肾功能下降更少,并发症风险低。
核心结论
- 基于高精度三维模型的3D AR在复杂肾肿瘤RAPN中有助于识别超声难以显示的病灶和肾内结构,可能改善切除质量并减少术后并发症。
研究设计与样本
- 回顾性研究,纳入2017年7月至2019年5月间91例复杂肾肿瘤(PADUA评分≥10)行RAPN的患者,48例接受3D AR引导,43例接受2D US引导。
主要发现
- 3D AR组整体缺血率为45.8%,2D US组为69.7%(p=0.03)。
- 3D AR组剜除率为62.5%,2D US组为37.5%(p=0.02)。
- 3D AR组集合系统损伤率为10.4%,2D US组为45.5%(p=0.003)。
- 术后3个月肾扫描估算肾血浆流量变化:3D AR组-12.38,2D US组-18.14(p=0.01)。
临床怎么用
- 对于复杂肾肿瘤(PADUA评分≥10)行机器人辅助肾部分切除术,可考虑使用3D AR引导以改善术中病灶识别和切除质量。
局限性
- 随访时间短。
- 样本量小。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Despite technical improvements introduced with robotic surgery, management of complex tumours (PADUA score ≥10) is still a matter of debate within the field of transperitoneal robot-assisted partial nephrectomy (RAPN). OBJECTIVE: To evaluate the accuracy of our three-dimensional (3D) static and elastic augmented reality (AR) systems based on hyperaccuracy models (HA3D) in identifying tumours and intrarenal structures during transperitoneal RAPN (AR-RAPN), compared with standard ultrasound (US). DESIGN, SETTING, AND PARTICIPANTS: A retrospective study was conducted, including 91 patients who underwent RAPN for complex renal tumours, 48 with 3D AR guidance and 43 with 2D US guidance, from July 2017 to May 2019. SURGICAL PROCEDURE: In patients who underwent 3D AR-RAPN, virtual image overlapping guided the surgeon during resection and suture phases. In the 2D US group, interventions were driven by US only. MEASUREMENTS: Patient characteristics were tested using the Fisher's exact test for categorical variables and the Mann-Whitney test for continuous ones. Intraoperative, postoperative, and surgical outcomes were collected. All results for continuous variables were expressed as medians (range), and frequencies and proportions were reported as percentages. RESULTS AND LIMITATIONS: The use of 3D AR guidance makes it possible to correctly identify the lesion and intraparenchymal structures with a more accurate 3D perception of the location and the nature of the different structures relative to the standard 2D US guidance. This translates to a lower rate of global ischaemia (45.8% in the 3D group vs 69.7% in the US group; p = 0.03), higher rate of enucleation (62.5% vs 37.5% in the 3D and US groups, respectively; p = 0.02), and lower rate of collecting system violation (10.4% vs 45.5%; p = 0.003). Postoperatively, 3D AR guidance use correlates to a low risk of surgery-related complications in 3D AR groups and a lower drop in estimated renal plasma flow at renal scan at 3 mo of follow-up (-12.38 in the 3D group vs -18.14 in the US group; p = 0.01). The main limitations of this study are short follow-up time and small sample size. CONCLUSIONS: HA3D models that overlap in vivo anatomy during AR-RAPN for complex tumours can be useful for identifying the lesion and intraparenchymal structures that are difficult to visualise with US only. This translates to a potential improvement in the quality of the resection phase and a reduction in postoperative complications, with better functional recovery. PATIENT SUMMARY: Based on our findings, three-dimensional augmented reality robot-assisted partial nephrectomy seems to help surgeons in the management of complex renal tumours, with potential early postoperative benefits.
引用
- Porpiglia F, Checcucci E, Amparore D, et al. Three-dimensional Augmented Reality Robot-assisted Partial Nephrectomy in Case of Complex Tumours (PADUA ≥10): A New Intraoperative Tool Overcoming the Ultrasound Guidance. Eur Urol. 2019. PMID: 31898992. doi:10.1016/j.eururo.2019.11.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。