文献速递前列腺癌

将临床相关模拟性能指标(CRPMS)整合并验证于新型全沉浸式保留神经机器人辅助根治性前列腺切除术(NS-RARP)模拟平台:基于三维打印与水凝胶注模技术

Incorporation and validation of clinically relevant performance metrics of simulation (CRPMS) into a novel full-immersion simulation platform for nerve-sparing robot-assisted radical prostatectomy (NS-RARP) utilizing three-dimensional printing and hydrogel casting technology.
PubMed 文献 · BJU Int · 2019-12-03

本研究利用患者MRI数据,通过三维打印注模和水凝胶注模技术制作解剖精确的骨盆、膀胱、前列腺、尿道及神经血管束(NVB)模型,模拟NS-RARP关键步骤。五名专家和九名新手完成模拟,量化NVB受力、切缘状态和尿道膀胱吻合(UVA)密封性,并用GEARS和RACE评分评估。结果显示专家任务时间更短、切缘更优、NVB受力更低,且GEARS/RACE评分与NVB受力及UVA漏率高度相关,表明该平台可用于机器人手术训练的实时评估与反馈。

要点

  • 专家在保留神经步骤任务时间更短(P=0.007),切缘结果更优(P=0.011)。
  • 专家NVB最大力、平均力、峰值频率和总能量均显著低于新手。
  • GEARS总分与NVB总能量相关(r=-0.87,P=0.000),RACE总分与UVA漏率相关(r=-0.86,P=0.000)。

核心结论

  • 基于三维打印和水凝胶注模的全沉浸式模拟平台可整合并验证NS-RARP的临床相关模拟性能指标。
  • GEARS和RACE等客观指标与NVB受力及UVA漏率相关,提示可用于机器人手术训练的实时评估与反馈。

研究设计与样本

  • 研究纳入5名专家(手术量>500例)和9名新手(手术量<50例)完成NS-RARP模拟。
  • 利用患者MRI数据,通过三维打印注模和水凝胶注模技术制作解剖精确的骨盆、膀胱、前列腺、尿道及NVB模型。
  • 模拟步骤包括膀胱颈解剖、精囊游离、NVB解剖和尿道膀胱吻合(UVA)。
  • 量化NVB受力(张力线传感器系统)、切缘状态(化学发光反应)和UVA密封性(180 mL漏测试)。
  • 由两名盲法外科医生进行GEARS和RACE客观评分。

主要发现

  • 专家组的保留神经任务时间更快(P=0.007),手术切缘结果更优(P=0.011)。
  • 专家组NVB受力显著更低:最大力(P=0.011)、平均力(P=0.011)、峰值频率(P=0.027)和总能量(P=0.003)。
  • GEARS力量敏感性子项和总分与NVB总能量(焦耳)相关,r值分别为-0.66(P=0.019)和-0.87(P=0.000)。
  • 专家组GEARS总分和力量敏感性评分显著高于新手组(P=0.003)。
  • UVA漏率与RACE总分高度相关(r=-0.86,P=0.000),新手与专家平均RACE评分有显著差异(P=0.003)。

关键数值与推荐

  • 专家组定义:手术量>500例;新手组定义:手术量<50例。
  • UVA密封性测试采用标准180 mL漏测试。
  • GEARS力量敏感性子项与NVB总能量相关(r=-0.66,P=0.019),GEARS总分与NVB总能量相关(r=-0.87,P=0.000)。
  • RACE总分与UVA漏率相关(r=-0.86,P=0.000)。

临床怎么用

  • 该模拟平台可用于NS-RARP手术技能的训练和评估,提供客观反馈。
  • GEARS和RACE评分可作为实时评估工具,帮助受训者改善NVB保护和吻合技术。
  • 需进一步研究验证平台预测真实手术 outcomes 的能力。

局限性

  • 研究仅纳入5名专家和9名新手,样本量小。
  • 模拟环境与真实手术存在差异,预测实际手术结果的能力需进一步评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To incorporate and validate clinically relevant performance metrics of simulation (CRPMS) into a hydrogel model for nerve-sparing robot-assisted radical prostatectomy (NS-RARP). MATERIALS AND METHODS: Anatomically accurate models of the human pelvis, bladder, prostate, urethra, neurovascular bundle (NVB) and relevant adjacent structures were created from patient MRI by injecting polyvinyl alcohol (PVA) hydrogels into three-dimensionally printed injection molds. The following steps of NS-RARP were simulated: bladder neck dissection; seminal vesicle mobilization; NVB dissection; and urethrovesical anastomosis (UVA). Five experts (caseload >500) and nine novices (caseload <50) completed the simulation. Force applied to the NVB during the dissection was quantified by a novel tension wire sensor system fabricated into the NVB. Post-simulation margin status (assessed by induction of chemiluminescent reaction with fluorescent dye mixed into the prostate PVA) and UVA weathertightness (via a standard 180-mL leak test) were also assessed. Objective scoring, using Global Evaluative Assessment of Robotic Skills (GEARS) and Robotic Anastomosis Competency Evaluation (RACE), was performed by two blinded surgeons. GEARS scores were correlated with forces applied to the NVB, and RACE scores were correlated with UVA leak rates. RESULTS: The expert group achieved faster task-specific times for nerve-sparing (P = 0.007) and superior surgical margin results (P = 0.011). Nerve forces applied were significantly lower for the expert group with regard to maximum force (P = 0.011), average force (P = 0.011), peak frequency (P = 0.027) and total energy (P = 0.003). Higher force sensitivity (subcategory of GEARS score) and total GEARS score correlated with lower nerve forces (total energy in Joules) applied to NVB during the simulation with a correlation coefficient (r value) of -0.66 (P = 0.019) and -0.87 (P = 0.000), respectively. Both total and force sensitivity GEARS scores were significantly higher in the expert group compared to the novice group (P = 0.003). UVA leak rate highly correlated with total RACE score r value = -0.86 (P = 0.000). Mean RACE scores were also significantly different between novices and experts (P = 0.003). CONCLUSION: We present a realistic, feedback-driven, full-immersion simulation platform for the development and evaluation of surgical skills pertinent to NS-RARP. The correlation of validated objective metrics (GEARS and RACE) with our CRPMS suggests their application as a novel method for real-time assessment and feedback during robotic surgery training. Further work is required to assess the ability to predict live surgical outcomes.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Witthaus MW, Farooq S, Melnyk R, et al. Incorporation and validation of clinically relevant performance metrics of simulation (CRPMS) into a novel full-immersion simulation platform for nerve-sparing robot-assisted radical prostatectomy (NS-RARP) utilizing three-dimensional printing and hydrogel casting technology. BJU Int. 2019. PMID: 31677325. doi:10.1111/bju.14940

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。