文献速递膀胱癌与上尿路尿路上皮癌

经皮影像引导粗针活检用于上尿路尿路上皮癌的安全性与诊断价值

Percutaneous Image-guided Core Needle Biopsy for Upper Tract Urothelial Carcinoma.
PubMed 文献 · Urology · 2019-10-23

本研究纳入42例在根治性肾输尿管切除术前接受经皮粗针活检的上尿路尿路上皮癌患者,评估其安全性、诊断阳性率及与术后病理的一致性。结果显示95%的活检与手术病理组织学一致,分级一致率90%,未发现针道种植转移。

要点

  • 经皮粗针活检与根治标本组织学一致率达95%,分级一致率90%。
  • Clavien 1-2级和3级并发症分别占14.3%和2.4%。
  • 中位随访28.2个月未发现影像学针道种植转移。

核心结论

  • 经皮粗针活检对上尿路尿路上皮癌是一种安全的诊断工具,具有高组织学阳性率和分级一致性。

研究设计与样本

  • 回顾性分析2009至2017年在本机构因上尿路尿路上皮癌行根治性肾输尿管切除术的444例患者,其中42例术前接受经皮粗针活检。

主要发现

  • 中位肿瘤大小为3.8 cm(范围1.2-10.2 cm),所有病变均起源于肾盂肾盏系统。
  • 52%(n=22)采用CT引导,48%(n=20)采用超声引导。
  • 95%的经皮粗针活检与根治性肾输尿管切除病理组织学一致。
  • 69%(n=29)的活检提供了组织学分级,其中90%(n=26)与手术病理分级一致。
  • Clavien 1-2级和3级并发症分别发生于14.3%(n=6)和2.4%(n=1)。

临床怎么用

  • 对于需要明确组织学诊断的上尿路尿路上皮癌患者,可考虑经皮粗针活检以获取组织学和分级信息。

局限性

  • 本研究为单中心回顾性分析,样本量较小(42例接受活检),选择偏倚可能存在。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To better understand the safety and diagnostic yield of percutaneous core-needle biopsy (PCNB) for upper tract urothelial carcinoma (UTUC). METHODS: Of 444 patients undergoing radical nephroureterectomy (RNU) for UTUC between 2009 and 2017 at our institution, 42 who had PCNB prior to RNU were identified for analysis. Endpoints included safety, diagnostic yield, and concordance with RNU pathology. PCNB specimens were deemed histologically concordant with RNU specimens for cases when cytologic evaluation of biopsy specimen and corresponding pathologic evaluation of RNU specimen both made a histologic diagnosis of urothelial carcinoma. RESULTS: Median tumor size was 3.8 cm (1.2-10.2 cm). All lesions arose from the pelvicalyceal system. CT-guidance was utilized in 52% (n = 22), and ultrasound-guidance in 48% (n = 20). Relative to RNU pathology, 95% of PCNBs demonstrated histologic concordance. Histologic grade was provided in 69% (n = 29) of PCNBs, with a 90% (n = 26) concordance with surgical pathology. Grades 1-2 and 3 complications occurred in 14.3% (n = 6) and 2.4% (n = 1), respectively. At a median follow-up of 28.2 months (range, 1.2-97.1 months) after biopsy, no cases of radiographic tract seeding were identified. CONCLUSION: In our cohort of 42 patients undergoing RNU for UTUC, PCNB appeared a safe diagnostic tool with high histologic yield and grade concordance. With greater than 2 years of follow-up, no cases of tract seeding were identified.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Joseph JP, Potretzke TA, Packiam V, et al. Percutaneous Image-guided Core Needle Biopsy for Upper Tract Urothelial Carcinoma. Urology. 2019. PMID: 31655078. doi:10.1016/j.urology.2019.10.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。