机器人辅助腹腔镜膀胱外交叉三角输尿管再植术联合裁剪治疗原发性梗阻性巨输尿管
本文描述了一种新型微创手术技术:机器人辅助腹腔镜膀胱外交叉三角输尿管再植术联合输尿管裁剪,并报告了13例原发性梗阻性巨输尿管患儿的病例系列。结果显示该技术安全可行、可重复,术后输尿管直径、肾盂直径及T1/2均显著改善。
要点
- 机器人辅助膀胱外交叉三角输尿管再植联合裁剪是治疗儿童原发性梗阻性巨输尿管的可行微创技术。
- 术后输尿管直径、肾盂直径及T1/2较术前显著下降,肾功能无显著变化。
- 术后并发症发生率为21%,均为Clavien-Dindo I-II级。
核心结论
- 机器人辅助交叉三角输尿管再植术联合输尿管裁剪在短期随访中安全、可行且可重复。
研究设计与样本
- 回顾性病例系列,纳入2017年4月至2019年5月期间接受机器人辅助腹腔镜膀胱外交叉三角输尿管再植术的13例原发性梗阻性巨输尿管患者,年龄10至96个月。
主要发现
- 中位年龄26个月(IQR 16-60),中位体重15 kg(IQR 10.1-31)。
- 中位控制台时间113分钟(IQR 90.5-140),中位术后住院2.5天(IQR 1.3-3)。
关键数值与推荐
- 术后并发症按Clavien-Dindo分级:3例(21%)出现并发症,其中1例I级(发热,自行缓解),2例II级(尿路感染)。
临床怎么用
- 对于原发性梗阻性巨输尿管患儿,机器人辅助膀胱外交叉三角输尿管再植联合裁剪可作为一种微创手术选择。
局限性
- 短期随访,样本量小(13例),缺乏对照组。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To describe a novel, minimally invasive surgical technique, robotic-assisted laparoscopic dismembered extravesical cross-trigonal ureteral reimplantation for primary obstructive megaureter and to report a case series of 13 patients. METHODS: Thirteen patients between the ages of 10 and 96 months who were diagnosed with primary obstructive megaureter underwent robotic-assisted laparoscopic dismembered extravesical cross-trigonal ureteral reimplantation between April 2017 and May 2019. The principle of this technique is performing an extravesical cross-trigonal ureteral reimplantation with intracorporeal tailoring of the ureter. This provides the advantage of achieving a long tunnel mimicking the Cohen cross-trigonal ureteral reimplantation, without performing the open surgical technique and offers the potential benefits of minimally invasive surgery. Surgical technique is described, demographic data and intra- and/or postoperative parameters are reported. RESULTS: Median age was 26 months (IQR 16-60). Median weight was 15 kg (IQR 10.1-31). Median console time was 113 minutes (IQR 90.5-140). Median postoperative stay was 2.5 days (IQR 1.3-3). Median ureteral diameter decreased from 17 mm (IQR 12.5-18.5) to 3 mm (IQR 0-6.5, P = .001). Median renal pelvis diameter decreased from 28 mm (IQR 20.5-37.8) to 4 mm (IQR 1.5-5, P = .005). Median renal function before surgery was 46% (IQR 24.5-48.5) and following surgery was 42% (IQR 36-42, P = .700). Median T1/2 decreased from 28 minutes (IQR 19.3-30) to 4.5 minutes (IQR 3-5, P = .009). Postoperative complications graded by the Clavien-Dindo classification were apparent in 3 patients (21%). One had grade I complication (fever, resolved spontaneously) and 2 had a Grade II complication (urinary tract infection). CONCLUSION: Robot-assisted cross-trigonal ureteral reimplantation with intracorporeal tailoring is safe, feasible, and reproducible in short-term follow-up.
引用
- Neheman A, Shumaker A, Gal J, et al. Robot-assisted Laparoscopic Extravesical Cross-trigonal Ureteral Reimplantation With Tailoring for Primary Obstructive Megaureter. Urology. 2019. PMID: 31542465. doi:10.1016/j.urology.2019.09.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。