文献速递前列腺癌

基于MRI-经直肠超声融合穿刺的前列腺癌新鲜组织生物样本库新技术

A New Technique in Fresh Prostate Cancer Tissue Biobanking Based on MRI-Transrectal Ultrasound Fusion Biopsy.
PubMed 文献 · Urology · 2019-09-02

研究提出并验证一种基于MRI-经直肠超声融合穿刺的前列腺癌新鲜冷冻组织生物样本库技术。对MRI可疑病灶重复穿刺,配对 cores 分别送病理和-80°C冻存。

要点

  • 配对穿刺法可准确预测冻存样本的组织学身份
  • 融合穿刺建库高效省时且组织质量高
  • RNA完整值范围6.8–9.3,均值7.89

核心结论

  • MRI-TRUS融合穿刺配对冻存法可准确预测生物样本的组织学身份,且RNA质量良好。

研究设计与样本

  • 2014年8月至2016年8月纳入PSA升高且MRI至少1个可疑病灶的患者,对每个可疑病灶同位置重复穿刺至少2针,配对标记为A/A'、B/B'等,A/B送病理,A'/B'冻存于-80°C。

主要发现

  • 冻存样本与对应石蜡样本在癌组织百分比和Gleason评分上无显著差异。
  • 20份冻存样本的RNA完整值范围为6.8至9.3,均值7.89。

关键数值与推荐

  • 60份冻存样本与石蜡样本诊断一致率为93.3%。
  • RNA完整值范围6.8–9.3,均值7.89。

临床怎么用

  • 该技术可用于前列腺癌新鲜冷冻组织的高效建库,组织学与RNA质量均满足后续研究需求。

局限性

  • 样本量有限,仅评估60份组织学样本和20份RNA样本,未报告长期随访或外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To present and validate a new technique for biobanking fresh-frozen prostate cancer tissue based on MRI-transrectal ultrasound fusion biopsy. MATERIALS AND METHODS: From August 2014 to August 2016, patients with elevated levels of PSA and at least 1 suspicious lesion on MRI were invited to this study. Each MRI-suspicious lesion was biopsied repeatedly for at least 2 cores in the same location. These repeated cores were labelled A/A', B/B', etc. The A/B cores were submitted for histologic assessment, and the corresponding A'/B' cores were stored in an -80°C freezer for biobanking. Sixty biobanked samples were processed for histologic assessment to compare their pathologic parameters with their corresponding paraffin samples. Another 20 biobanked samples were processed for RNA quality evaluation. RESULTS: Fifty-six of the 60 selected banking samples matched their corresponding paraffin samples for benign vs malignant diagnosis, leading an overall concordance rate of 93.3%. There was no significant difference between banking samples and the corresponding paraffin samples in cancer percentage and Gleason score. The RNA Integrity Number value ranged from 6.8 to 9.3 (mean 7.89). CONCLUSION: The current study demonstrates that the histologic identity of the banked prostate biopsy sample can be accurately predicted by its corresponding paraffin samples. MRI-TRUS fusion biopsy based biobanking method is highly efficient, timesaving, and has high quality tissues both at the histologic and RNA integrity levels.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Ji C, Wang W, Lu Q, et al. A New Technique in Fresh Prostate Cancer Tissue Biobanking Based on MRI-Transrectal Ultrasound Fusion Biopsy. Urology. 2019. PMID: 31487510. doi:10.1016/j.urology.2019.08.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。