文献速递前列腺癌

前列腺多参数磁共振成像在非裔美国男性中的诊断效能

Diagnostic Performance of Prostate Multiparametric Magnetic Resonance Imaging in African-American Men.
PubMed 文献 · Urology · 2019-08-13

本研究比较了非裔美国男性与白人男性前列腺多参数磁共振成像(mpMRI)检测前列腺癌的效能,以PI-RADS 4或5类为阳性、Gleason分级组≥2为结局阳性。非匹配组(非裔60例、白人541例)及倾向性评分1:2匹配后,两组敏感性、特异性、阳性预测值、阴性预测值及活检升级率均无显著差异。作者建议不应基于种族决定是否行mpMRI。

要点

  • 非裔美国男性与白人男性mpMRI检测前列腺癌的敏感性、特异性无显著差异。
  • 两组阳性预测值、阴性预测值及靶向与系统活检间升级率均无显著差异。
  • 作者建议不应基于种族保留或优先提供mpMRI。

核心结论

  • 非裔美国男性与白人男性使用mpMRI检测前列腺癌的结局相似,作者建议不应基于种族保留或优先提供mpMRI。

研究设计与样本

  • 回顾性分析2014年10月至2017年6月活检前接受前列腺mpMRI的男性数据库,共601例(非裔美国男性60例,白人男性541例)。
  • 以PI-RADS 4或5类为试验阳性,任何活检针Gleason分级组≥2为结局阳性。
  • 采用倾向性评分卡钳匹配算法,按年龄、PSA和PSA密度以1:2比例匹配非裔美国男性与白人男性进行亚组分析。

主要发现

  • 非匹配组非裔美国男性 vs 白人男性敏感性86.7% vs 83.6%(P=1.00),特异性45.9% vs 49.1%(P=.71),阳性预测值50.0% vs 46.9%,阴性预测值85.0% vs 84.8%(P=1.00),均无显著差异。
  • 匹配比较中亦观察到相似结果。
  • 靶向与系统活检针之间的升级率在非匹配组非裔美国男性 vs 白人男性为12.2% vs 15.8%(P=.66),匹配组为12.2% vs 12.8%(P=.92),均无统计学差异。

关键数值与推荐

  • 试验阳性定义为PI-RADS分类4或5类。
  • 结局阳性定义为任何活检针Gleason分级组≥2。
  • 倾向性评分匹配变量为年龄、PSA和PSA密度,匹配比例1:2。

临床怎么用

  • 作者建议,使用mpMRI检测前列腺癌时不应基于种族保留或优先提供该检查。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare test performance of multiparametric magnetic resonance imaging (mpMRI) for detection of prostate cancer (PCa) in African-American men (AAM) and white men (WM) using the Prostate Imaging Reporting and Data System in unmatched groups as well as a cohort matched for clinical factors. METHODS: We examined our database of men who underwent prostate mpMRI prior to biopsy between October 2014 and June 2017 (n = 601; 60 AAM, 541 WM). Test performance was defined using Prostate Imaging Reporting and Data System classification 4 or 5 considered test positive and Gleason grade group 2 or greater from any biopsy core considered outcome positive. A subset analysis was performed using a propensity score caliper matching algorithm to match AAM to WM in a 1:2 ratio using the variables age, PSA, and PSA density. RESULTS: No significant differences in test performance were found with similar sensitivity (86.7% vs 83.6, P = 1.00), specificity (45.9% vs 49.1%, P = .71), positive predictive value (50.0% vs 46.9%), and negative predictive value (85.0% vs 84.8%, P = 1.00) for AAM and WM. Similar results were noted in our matched comparison. The rate of upgrading between targeted and systematic biopsy cores did not statistically differ between AAM and WM in both unmatched (12.2% vs. 15.8%, P = .66) and matched (12.2% vs 12.8%, P = .92) comparisons. CONCLUSION: Our findings provide supporting evidence that AAM have similar outcomes to WM in PCa detection using mpMRI. We suggest that mpMRI should not be withheld or offered preferentially on the basis of race when used for the detection of PCa.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Henning GM, Vetter JM, Drake BF, et al. Diagnostic Performance of Prostate Multiparametric Magnetic Resonance Imaging in African-American Men. Urology. 2019. PMID: 31419432. doi:10.1016/j.urology.2019.08.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。