文献速递前列腺癌

前列腺对比增强经直肠超声评估与全 mount 前列腺切除标本的相关性研究

Prostate Contrast Enhanced Transrectal Ultrasound Evaluation of the Prostate With Whole-Mount Prostatectomy Correlation.
PubMed 文献 · Urology · 2019-08-01

研究纳入58例接受对比增强经直肠超声(CE-TRUS)及后续根治性前列腺切除全mount病理的受试者,比较基线TRUS与CE-TRUS各成像模式对前列腺癌的诊断准确性。CE-能量多普勒和闪烁再灌注成像的Az显著高于基线成像,两者联合进一步改善诊断准确性,对临床显著肿瘤体积>1 cc者诊断准确性更佳。

要点

  • CE-TRUS的Az最高为CE-能量多普勒0.66和闪烁再灌注成像0.64,均显著高于基线(P=.04)。
  • CE-能量多普勒联合闪烁再灌注成像Az为0.70,优于基线成像的0.59(P=.006)。
  • 对临床显著肿瘤体积>1 cc者,诊断准确性进一步提高。

核心结论

  • 对比增强超声的诊断准确性高于基线成像,对临床显著肿瘤体积>1 cc者诊断准确性进一步提高。

研究设计与样本

  • 纳入58例接受CE-TRUS及后续根治性前列腺切除全mount病理的受试者,比较基线TRUS与CE-TRUS各成像模式与全mount病理的一致性。
  • 每位患者接受基线TRUS及静脉输注全氟丙烷脂质微球(Definity)的CE-TRUS评估,采用主观5分评分法对前列腺每个六分区在3种基线成像模式和5种对比增强成像模式下评分。
  • 采用聚类逻辑回归模型比较各超声成像模式检测前列腺癌的受试者工作特征曲线下面积(Az)。

主要发现

  • 58例全mount标本中,最高Gleason评分6分29例、7分24例、8分5例。
  • 基线TRUS参数的Az:灰阶0.55、彩色多普勒0.61、能量多普勒0.59。
  • CE-TRUS参数Az显著增加,最高为CE-能量多普勒0.66和闪烁再灌注成像0.64(与基线比较P=.04)。
  • CE-能量多普勒联合闪烁再灌注成像的Az为0.70,优于基线成像的0.59(P=.006)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate the diagnostic accuracy of contrast enhanced transrectal ultrasound (CE-TRUS) in comparison with whole-mount radical prostatectomy specimens. METHOD AND MATERIALS: Fifty-eight subjects who underwent CE-TRUS and subsequent radical prostatectomy with whole-mount pathology were included in the study. Each patient underwent evaluation with baseline TRUS and again during CE-TRUS with intravenous infusion of perflutren lipid microsphere (Definity, Lantheus Medical Imaging, N Billerica, MA). A subjective 5 point scale was used to rate each sextant of the prostate in 3 baseline imaging modes and in 5 contrast-enhanced imaging modes. Baseline TRUS and CE-TRUS findings were compared with digitized whole-mount findings. A clustered logistic regression model was computed to compare the area under the receiver operating characteristic curve (Az) for detection of prostate cancer by various modes of ultrasound imaging. RESULTS: Among the 58 whole-mount specimens, a maximum Gleason score of 6 was identified in 29 subjects, a score of 7 was identified in 24 and a score of 8 was identified in 5. The Az for baseline TRUS parameters was 0.55 for grayscale, 0.61 for color Doppler and 0.59 for power Doppler. CE-TRUS parameters demonstrated significant increases in Az with the highest Az for CE-power Doppler (0.66) and flash replenishment imaging (0.64) (P = .04 for comparison to baseline). The combination of CE-power Doppler and flash replenishment imaging resulted in improved Az compared with baseline imaging (0.70 vs 0.59, P= .006). CONCLUSION: Contrast-enhanced ultrasonography demonstrates greater diagnostic accuracy than baseline imaging. Diagnostic accuracy is further improved for "clinically significant" tumor volumes >1 cc.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Trabulsi EJ, Calio BP, Kamel SI, et al. Prostate Contrast Enhanced Transrectal Ultrasound Evaluation of the Prostate With Whole-Mount Prostatectomy Correlation. Urology. 2019. PMID: 31377256. doi:10.1016/j.urology.2019.07.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。