机器人部分肾切除术中采用早期松开阻断技术减少假性动脉瘤和尿漏:结果分析
该单机构回顾性研究纳入2009至2018年因疑似肾恶性肿瘤行机器人部分肾切除术并采用早期松开阻断技术的463例患者,报告平均手术时间186分钟、热缺血时间14.7分钟、估计失血量242毫升,30天并发症率14.7%(其中88%为Clavien I-II级),尿漏1例(0.2%),输血率1.33%,假性动脉瘤率0%。作者结论认为该技术可靠安全,假性动脉瘤和尿漏率低,与其他已发表技术相比具有优势。
要点
- 早期松开阻断技术用于机器人部分肾切除术,假性动脉瘤率为0%,尿漏率0.2%。
- 30天并发症率14.7%,其中88%为Clavien I-II级,输血率1.33%。
- 平均手术时间186分钟,热缺血时间14.7分钟,估计失血量242毫升。
核心结论
- 作者认为机器人部分肾切除术中采用早期松开阻断技术可靠且安全,假性动脉瘤率和尿漏率低,与其他已发表技术相比具有优势。
研究设计与样本
- 单机构回顾性综述,基于前瞻性维护数据库,纳入2009年至2018年因疑似肾恶性肿瘤行机器人部分肾切除术并采用早期松开阻断技术的患者,共463例。
主要发现
- 平均手术时间为186分钟,平均热缺血时间为14.7分钟,平均估计失血量为242 cc。
- 30天术后并发症率为14.7%,其中88%为Clavien I-II级。
- 尿漏发生于1例(0.2%)同时行部分肾切除术和肾盂切开取石术治疗部分鹿角形结石的患者。
- 术后输血率为1.33%,假性动脉瘤率为0%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To present our experience using the early unclamping technique for robotic partial nephrectomy with particular attention to delayed complications, namely pseudoaneurysm and urine leak. We hypothesized that early hilar unclamping allows for improved control of end arteries and renorrhaphy after tumor resection, reducing overall delayed complications after partial nephrectomy with no increased risk of blood transfusion. METHODS: This single institution retrospective review of a prospectively maintained database includes patients undergoing robotic partial nephrectomy with early unclamping technique for presumed renal malignancy between 2009 and 2018. Patient demographics and perioperative parameters are described, particularly rates of pseudoaneurysm and urine leak. Results are compared to previously published partial nephrectomy studies using various clamping and renorrhaphy techniques. RESULTS: Four hundred and sixty three patients were included in the study. Mean operative time and warm ischemia time were 186 and 14.7 minutes, respectively. Mean estimated blood loss was 242 cc. Thirty-day postoperative complication rate was 14.7%, with 88% of these Clavien I-II. Urine leak occurred in 1 patient (0.2%) undergoing a simultaneous partial nephrectomy and pyelothitotomy for partial staghorn stone. Postoperative transfusion rate was 1.33% and our pseudoaneurysm rate was 0%. CONCLUSION: The early unclamping technique for robotic partial nephrectomy is reliable and safe, with low pseudoaneurysm and urine leak rates which compare favorably to other published techniques.
引用
- Delto JC, Chang P, Hyde S, et al. Reducing Pseudoaneurysm and Urine Leak After Robotic Partial Nephrectomy: Results Using the Early Unclamping Technique. Urology. 2019. PMID: 31254571. doi:10.1016/j.urology.2019.05.042