弯导丝与直导丝骶神经调节的两年临床结局比较
单中心前瞻性研究纳入40例膀胱过度活动症和15例非梗阻性尿潴留患者,比较标准化倒钩电极植入技术中使用弯导丝与直导丝的结局。弯导丝组手术成功率94%,直导丝组65%(P=0.005);24个月时成功率分别为91% vs 45%(P<0.001),弯导丝组最佳电极配置比例更高(60% vs 40%)。
要点
- 弯导丝组倒钩电极植入成功率显著高于直导丝组(94% vs 65%)。
- 24个月时弯导丝组成功率91%,直导丝组降至45%。
- 弯导丝组最佳电极配置占60%,优于直导丝组的40%。
核心结论
- 标准化植入技术使用弯导丝较直导丝获得更高的倒钩电极植入成功率、2年随访成功率和更多最佳电极配置。
研究设计与样本
- 单中心前瞻性研究,2013年8月至2015年6月纳入40例膀胱过度活动症和15例非梗阻性尿潴留患者。
- 主要结局为按意向性分析12和24个月的倒钩电极手术成功,次要结局为编程时最佳电极配置数量。
主要发现
- 弯导丝组35例中33例(94%)手术成功,直导丝组20例中13例(65%)成功(P=0.005)。
- 意图性分析12和24个月成功率:弯导丝组94%和91%,直导丝组65%和45%(P=0.002和P<0.001)。
- 弯导丝组60%电极配置为最佳、25%为差,直导丝组分别为40%和37%(P<0.001)。
临床怎么用
- 在标准化倒钩电极植入技术中优先选用弯导丝可能提高骶神经调节的植入成功率和中期疗效。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To assess clinical follow-up data over 24 months, comparing the use of a curved vs straight stylet in patients undergoing sacral neuromodulation using the standardized tined lead implantation technique. PATIENTS AND METHODS: We conducted a single tertiary-centre, prospective study between August 2013 and June 2015 involving 40 patients with overactive bladder and 15 with non-obstructive urinary retention refractory to first-line treatment. The primary outcome was successful tined lead procedure according to intention-to-treat analyses at 12 and 24 months. The secondary outcome was number of optimal electrode configurations during programming. Statistical analysis was performed using plain non-parametric tests for numerical and categorical data. RESULTS: Successful tined lead procedures were achieved in 33 of 35 patients (94%) implanted with the curved stylet compared with 13 of 20 patients (65%) implanted with the straight stylet (P = 0.005). Intention-to-treat analyses at 12 and 24 months showed success rates of 94% and 91%, respectively, in the curved stylet group vs 65% and 45%, respectively, in the straight stylet group (P = 0.002 and P < 0.001). In the curved stylet group, 60% and 25% of the electrode configurations were considered optimal and poor, respectively, vs 40% and 37%, respectively, in the straight stylet group (P < 0.001). CONCLUSIONS: The use of the standardized implantation technique with the curved stylet led to more successful tined lead procedures, better success rates after 2 years of follow-up and a greater number of optimal electrode configurations when compared to use of the straight stylet.
引用
- Vaganée D, Kessler TM, Van de Borne S, et al. Sacral neuromodulation using the standardized tined lead implantation technique with a curved vs a straight stylet: 2-year clinical outcomes and sensory responses to lead stimulation. BJU Int. 2019. PMID: 30537223. doi:10.1111/bju.14650