文献速递泌尿系结石

泌尿系结石患者KUB平片的辐射剂量不容忽视

Radiation From Kidney-Ureter-Bladder Radiographs Is Not Trivial.
PubMed 文献 · Urology · 2018-12-04

结果显示KUB平均有效剂量为2.15 mSv±1.67 mSv,仅26%检查低于1 mSv,BMI、腹部厚度和图像数量均与剂量增加相关(P<.01)。

要点

  • KUB平均有效剂量2.15 mSv,约为常引用值的2倍
  • 仅26%的KUB检查有效剂量低于1 mSv
  • BMI、腹部厚度和图像数量与剂量增加相关(P<.01)

核心结论

  • 当代泌尿系结石患者的KUB检查有效剂量约为常引用值的2倍。
  • 有效剂量增加与患者体型增大和采集图像数量增多相关。
  • 近1/5患者的KUB有效剂量与低剂量CT相当。

研究设计与样本

  • KUB有效剂量采用基于蒙特卡洛的模拟程序估算,CT利用报告的剂量长度乘积估算。
  • 分析年龄、性别、BMI和腹部直径与有效剂量的关联,并比较外院与本地KUB。

主要发现

  • 92.6%的KUB包含多张X线图像。
  • KUB平均有效剂量为2.15 mSv±1.67 mSv。
  • 仅26%的检查有效剂量低于1 mSv。
  • BMI、腹部厚度和图像数量均与剂量增加相关(P<.01 each)。
  • 88%的外院检查包含多张图像。

临床怎么用

  • 应重新审视KUB在泌尿系结石中的角色,考虑其有限的敏感性和特异性、相关辐射及其他影像选择。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To estimate effective dose of kidney-ureter-bladder (KUB) radiographs in a contemporary population of patients with urolithiasis. METHODS: A retrospective review was performed to identify patients visiting a urology clinic for urolithiasis where a KUB was obtained and whom had a recent computed tomography (CT). Effective dose for KUBs was estimated using a Monte Carlo based simulation program and for CT utilizing the reported dose-length-product. Age, gender, body mass index, and abdominal diameter were analyzed for association with effective dose. KUBs performed at outside facilities in referred patient were compared to those obtained locally when available. RESULTS: Fifty-four patients were identified meeting criteria. The majority (92.6%) of KUBs contained multiple radiographs. Mean effective dose was 2.15 mSv ± 1.67 mSv. Only 26% of examinations effective dose was under 1 mSv. Body mass index, abdominal thickness, and image count were all associated with an increase in dose (P < .01 each). Similar to local KUBs, 88% of outside examinations contained multiple images. CONCLUSION: KUB examinations in this contemporary setting are associated with a 2-fold higher effective dose then is often referenced. Increased effective dose is associated with increased patient size and number of images acquired. Nearly 1 in 5 patient's KUB effective dose was similar to a low-dose CT. KUBs role should be re-examined given its limited sensitivity, specificity, associated radiation, and other available imaging options.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Kuebker J, Shuman J, Hsi RS, et al. Radiation From Kidney-Ureter-Bladder Radiographs Is Not Trivial. Urology. 2018. PMID: 30528717. doi:10.1016/j.urology.2018.11.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。