低强度脉冲超声影响压力性尿失禁大鼠模型肌卫星细胞的成肌分化
本研究在大鼠压力性尿失禁模型中探讨低强度脉冲超声(LIPUS)的治疗效果及其对肌卫星细胞的影响。结果显示200和300 mW/cm2 LIPUS组漏尿点压力和膀胱容量恢复,200 mW/cm2组横纹肌再生更明显,LIPUS激活肌卫星细胞成肌分化并与p38磷酸化水平相关。
要点
- 200和300 mW/cm2 LIPUS可恢复SUI大鼠的漏尿点压力和膀胱容量。
- 200 mW/cm2 LIPUS组横纹肌再生较无治疗对照组更显著。
- LIPUS激活肌卫星细胞成肌分化,与p38磷酸化水平相关。
核心结论
- LIPUS可恢复SUI大鼠模型的漏尿点压力和膀胱容量,并激活肌卫星细胞成肌分化。
主要发现
- 200和300 mW/cm2 LIPUS组漏尿点压力和膀胱容量恢复,100 mW/cm2组未恢复。
- 200 mW/cm2 LIPUS组较SUI无治疗对照组观察到更显著的横纹肌再生。
- LIPUS激活肌卫星细胞成肌分化,且与p38磷酸化水平相关。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To investigate the therapeutic effect of low intensity pulsed ultrasound (LIPUS) in a stress urinary incontinence (SUI) rat model and its influence on myogenic satellite cells. METHODS: Fifty Sprague-Dawley rats underwent vaginal distension and bilateral ovariectomy mimicking partum injury and menopause to construct SUI models, which were further randomized into 100 mW/cm2 LIPUS, 200 mW/cm2 LIPUS, 300 mW/cm2 LIPUS, and none-treatment control subgroups with 10 rats per subgroup. Ten rats served as mock operation control. Leak point pressure and bladder capacity were recorded 1 week after LIPUS treatment. Immunofluorescence staining and Western blot were performed to examine histological changes, myodifferentiation, and signaling pathway. RESULTS: Here,we found the leak point pressure and bladder capacity were restored in 200 mW/cm2 LIPUS and 300 mW/cm2 LIPUS groups, but not in 100 mW/cm2 LIPUS group. More robust striated muscle regeneration was observed in 200 mW/cm2 LIPUS group comparing with the SUI none-treatment group. Moreover, we found LIPUS activated the myodifferentiation of muscle satellite cells, which is correlated to p38 phosphorylation level. CONCLUSION: LIPUS restored the leak point pressure and bladder capacity, and activated satellite cell myodifferentiation in SUI rat model.
引用
- Yang B, Li M, Lei H, et al. Low Intensity Pulsed Ultrasound Influences the Myogenic Differentiation of Muscle Satellite Cells in a Stress Urinary Incontinence Rat Model. Urology. 2018. PMID: 30273612. doi:10.1016/j.urology.2018.09.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。