术后多普勒超声对肾部分切除术后无症状假性动脉瘤早期检出及出血并发症预防价值
中位术后7天检出1例无症状肾动脉假性动脉瘤(1.2%),予以预防性栓塞;未见术后出血并发症,无人需输血。结果提示术后早期多普勒超声可能有助于筛查假性动脉瘤并降低出血风险。
要点
- 机器人辅助肾部分切除术后早期多普勒超声可检出无症状肾动脉假性动脉瘤。
- 研究期间无术后出血并发症,无患者需输血,支持DUS筛查的潜在临床价值。
核心结论
- 本组患者未发生出血并发症,但检出1例无症状假性动脉瘤并经早期DUS诊断后预防性栓塞处理。
- 结果提示术后早期DUS筛查假性动脉瘤可能降低肾部分切除术后出血并发症风险。
研究设计与样本
- 回顾性研究,纳入2015至2017年所有连续接受机器人辅助肾部分切除术的肾肿瘤患者。
- 所有患者术后早期接受肾多普勒超声检查,评估假性动脉瘤、动静脉畸形或积液及出血并发症、输血/栓塞需求。
主要发现
- 平均肿瘤大小31(±13.1)mm,中位RENAL肾测量评分6(范围4-11),平均热缺血时间22(±7)min。
- 12例(14.5%)使用止血剂;术后DUS中位时间7(四分位距6-8)天。
- DUS检出1例无症状假性动脉瘤(1.2%),接受预防性栓塞,为唯一Clavien III级并发症患者。
- 20例(24%)发生Clavien I/II级并发症;无患者出现术后出血并发症,无患者需输血。
临床怎么用
- 机器人辅助肾部分切除术后可考虑早期行肾多普勒超声筛查无症状假性动脉瘤。
- 对DUS检出的无症状假性动脉瘤可行预防性动脉栓塞以降低术后出血风险。
局限性
- 原文未设对照组,DUS的临床效用需进一步前瞻性研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess the clinical utility of systematic Doppler ultrasonography (DUS) after robot-assisted partial nephrectomy (PN) for the detection of renal artery pseudoaneurysm (PA) and to allow pre-emptive arterial embolization to reduce the postoperative bleeding risk. MATERIALS AND METHODS: A retrospective study was conducted including all consecutive patients treated with robot-assisted PN for renal tumours between 2015 and 2017. Every patient underwent renal DUS in the early postoperative period. The presence of PA, arteriovenous malformation or collection on the DUS, as well as the incidence of haemorrhagic complications and need for transfusion/embolization were assessed. RESULTS: Eighty-three patients were included, with a median (range) age of 58 (19-80) years. The median (range) follow-up was 5 (1-30) months. The mean (±sd) tumour size was 31 (±13.1) mm, the median (range) RENAL nephrometry score was 6 (4-11), and the mean (±sd) warm ischaemia time was 22 (±7) min. A haemostatic agent was used in 12 patients (14.5%). No patient encountered haemorrhagic complications postoperatively, and no patient required transfusion. The median (interquartile range) time to DUS postoperatively was 7 (6-8) days. DUS revealed one asymptomatic PA (1.2%), which was treated with pre-emptive embolization. This was the only patient who encountered a Clavien grade III complication, while 20 patients (24%) had a complication grade I/II. CONCLUSIONS: No haemorrhagic complications occurred in the present study population, although one asymptomatic PA was found. It was diagnosed early with DUS, allowing pre-emptive management with embolization. These results suggest the potential clinical utility of early postoperative DUS in order to screen for PA to reduce the risk of post-PN haemorrhagic complications.
引用
- Nouhaud FX, Williams M, Arnfield E, et al. Is postoperative Doppler ultrasonography useful for the early detection of asymptomatic pseudoaneurysm and prevention of haemorrhagic complications after partial nephrectomy? BJU Int. 2018. PMID: 30370984. doi:10.1111/bju.14485
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。