文献速递肾癌与肾肿瘤

新型压电驱动脉冲水射流系统对大鼠部分肾切除后残肾功能的影响

Effects of a Novel Piezo Actuator-driven Pulsed Water Jet System on Residual Kidney After Partial Nephrectomy in a Rat Model.
PubMed 文献 · Urology · 2018-10-22

本研究在大鼠模型中评估新型压电驱动脉冲水射流(ADPJ)系统行非阻断部分肾切除后的肾损伤。结果显示ADPJ组血尿素氮、肌酐及尿/血清KIM-1显著低于软凝组,1-甲基腺苷免疫染色范围及KIM-1 mRNA表达也更低。提示ADPJ可能减轻非阻断部分肾切除后的肾损伤。

要点

  • ADPJ系统行非阻断部分肾切除,血尿素氮和肌酐显著低于软凝组。
  • ADPJ组尿和血清KIM-1水平及肾组织KIM-1 mRNA表达均更低。
  • ADPJ组1-甲基腺苷免疫染色范围显著小于热凝器械组。

核心结论

  • 压电ADPJ系统可能减轻非阻断部分肾切除后的肾损伤。

研究设计与样本

  • Sprague-Dawley大鼠分为4组:假手术、ADPJ非阻断部分肾切除、无线电刀、软凝。
  • 术后1、7、14、30、90天采集尿和血样本并获取残肾组织。

主要发现

  • ADPJ组血清血尿素氮和肌酐显著低于软凝组。
  • ADPJ组尿和血清KIM-1水平显著降低。
  • ADPJ组1-甲基腺苷免疫染色范围显著少于热凝器械。
  • ADPJ组KIM-1 mRNA表达水平也更低。

临床怎么用

  • ADPJ系统或可作为非阻断部分肾切除中减少热损伤的器械选择。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate renal damage after off-clamp partial nephrectomy (PN) using a novel surgical device, piezo actuator-driven pulsed water jet (ADPJ) system. METHODS: Sprague-Dawley rats were divided into 4 groups and subjected to sham operation, off-clamp PN by the piezo ADPJ system, radio knife, and soft coagulation, which have been used as thermal coagulation devices. Urine and blood samples were collected, and residual kidneys were harvested at 1, 7, 14, 30, and 90 days after PN. Serum blood urea nitrogen, creatinine, and urinary and serum kidney injury molecule-1 KIM-1 levels were measured. Morphological features and the extent of renal ischemia of resection surfaces were evaluated by hematoxylin-eosin staining and immunostaining using antibodies to 1-methyladenosine, respectively. In addition, the expression levels of KIM-1 mRNA extracted from each resection surface were analyzed by quantitative real-time reverse transcription polymerase chain reaction. RESULTS: Serum blood urea nitrogen and creatinine were significantly lower with the piezo ADPJ system than with soft coagulation. Urinary and serum KIM-1 levels were also significantly decreased with the ADPJ. The extent of 1-methyladenosine immunostaining was significantly less with the ADPJ than with thermal coagulation devices. The expression levels of KIM-1 mRNA were also lower in the ADPJ system group. CONCLUSION: The piezo ADPJ system might attenuate renal damage after off-clamp PN.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Kamiyama Y, Yamashita S, Nakagawa A, et al. Effects of a Novel Piezo Actuator-driven Pulsed Water Jet System on Residual Kidney After Partial Nephrectomy in a Rat Model. Urology. 2018. PMID: 30359707. doi:10.1016/j.urology.2018.10.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。