离体CT半自动分割测量泌尿系结石大小的准确性:与X线手工测量的对照研究
本研究纳入103例泌尿系结石患者(32女、71男,平均年龄52岁±18),对收集的结石行标准化离体CT扫描和X线摄影,比较半自动分割(syngo.via)与X线手工卡尺测量的结石大小。CT平均4.4 mm、X线平均4.6 mm,两种方法总体测量无显著差异,相关性中至优,半自动分割可减少测量误差,尤其利于小结石。
要点
- CT半自动分割与X线手工测量结石大小总体无显著差异。
- 两种方法相关性依每例分析结石数目不同呈中至优。
- 半自动分割减少测量误差,对小体积结石更精确。
核心结论
- CT半自动分割测量泌尿系结石大小可行,可减少测量误差,尤其能更精确评估较小结石。
研究设计与样本
- 纳入103例确诊泌尿系结石并收集结石的患者(32女、71男,平均年龄52岁±18),对结石行标准化离体CT扫描和X线摄影。
- 采用商业软件(syngo.via,Siemens,德国)对结石大小行半自动分割,并与数字X线摄影上的手工卡尺测量比较。
主要发现
- 结石平均大小在CT为4.4 mm、在X线摄影为4.6 mm。
- 依每例患者分析的结石数目不同,两种方法对结石大小的估计显示中至优的相关性。
- 两种方法总体大小测量无显著差异。
临床怎么用
- CT半自动分割可作为结石大小测量的辅助手段,以减少测量误差并提高小结石的评估精度。
- 当结石邻近时,半自动分割可能受影响,需注意测量结果的可靠性。
局限性
- 邻近结石可能妨碍结石大小的半自动分割。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the accuracy of semiautomated segmentation of urinary stone size in computed tomography (CT) compared with manual measurement. MATERIALS AND METHODS: A total of 103 patients (32f, 71m ; mean age 52 years±18 that were diagnosed with urolithiasis and collected stones received standardized ex vivo CT-scans and radiography of the stones. Stone size was segmented semiautomatically using commercial software (syngo.via, Siemens, Germany) and compared with manual caliper measurement on digital radiography. RESULTS: Mean size was 4.4 mm in CT and 4.6 mm in radiography. Depending on number of stones analyzed per patient, estimation of stone size showed moderate to excellent correlation for both methods. There was no significant difference in overall size measurement. CONCLUSION: Semiautomatic segmentation of urinary stone size in CT is possible and reduces measurement errors, allowing more precise estimation especially for smaller concrements. Neighboring stones may hamper segmentation of stone size.
引用
- Niemann T, Jerjen I, Hefermehl L, et al. Accuracy of Ex Vivo Semiautomatic Segmentation of Urinary Stone Size in Computed Tomography Compared With Manual Size Estimation in Radiographic Correlation. Urology. 2018. PMID: 30076939. doi:10.1016/j.urology.2018.06.044
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。