文献速递前列腺增生与排尿功能障碍男科与性医学

3.5厘米人工尿道括约肌袖套的侵蚀率与较大袖套相似

Erosion rates of 3.5-cm artificial urinary sphincter cuffs are similar to larger cuffs.
PubMed 文献 · BJU Int · 2018-08-09

该研究回顾性分析了410例接受人工尿道括约肌(AUS)植入的男性压力性尿失禁患者,比较3.5 cm袖套与≥4.0 cm袖套的长期结局和侵蚀率。中位随访50个月,两组袖套侵蚀率相近(10.8% vs 10.7%,P=0.7),控尿成功率亦无显著差异(82% vs 90%,P=0.1)。盆腔放疗史、既往袖套侵蚀、既往尿道成形术及阴茎假体植入史与袖套侵蚀相关。

要点

  • 3.5 cm袖套与≥4.0 cm袖套的侵蚀率相似(10.8% vs 10.7%)。
  • 两组控尿成功率无显著差异(82% vs 90%,P=0.1)。
  • 盆腔放疗史患者袖套侵蚀风险更高,与袖套尺寸无关。

核心结论

  • 3.5 cm AUS袖套在有效性和尿道侵蚀率方面与≥4.0 cm袖套相似。
  • 有盆腔放疗史的患者袖套侵蚀风险更高,无论袖套尺寸。

研究设计与样本

  • 回顾性队列研究,纳入2009年9月至2017年6月由单一术者行AUS植入的410例男性压力性尿失禁患者。
  • 采用统一会阴入路,在精确测量海绵体后于最近端球部尿道放置袖套。
  • 按袖套尺寸和放疗状态分层,分析 demographics 和手术结局。

主要发现

  • 3.5 cm袖套组166例(40.5%),≥4.0 cm袖套组244例(59.5%)。
  • 中位随访50个月,44例发生袖套侵蚀,3.5 cm组10.8%(18/166),≥4.0 cm组10.7%(26/244),P=0.7。
  • 多因素logistic回归显示,与袖套侵蚀相关的临床因素包括盆腔放疗史、既往袖套侵蚀、既往尿道成形术和既往阴茎假体植入史。
  • 两组患者人口学特征相似,包括年龄、BMI、合并症、吸烟史、放疗史、既往AUS和既往IPP植入。
  • 控尿成功率(每天≤1片尿垫)在3.5 cm组为82%,≥4.0 cm组为90%,P=0.1。

关键数值与推荐

  • 袖套侵蚀率:3.5 cm组10.8%(18/166),≥4.0 cm组10.7%(26/244),P=0.7。
  • 控尿成功率:3.5 cm组82%,≥4.0 cm组90%,P=0.1。
  • 中位随访时间50个月。

临床怎么用

  • 3.5 cm袖套可作为合适患者的选项,其侵蚀率和控尿效果与较大袖套相当。
  • 对有盆腔放疗史、既往袖套侵蚀、尿道成形术或阴茎假体植入史的患者,应告知袖套侵蚀风险较高。

局限性

  • 回顾性研究,单术者经验,可能存在选择偏倚。
  • 未报告具体放疗剂量、手术细节及患者报告结局的详细数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare long-term outcomes and erosion rates of 3.5-cm artificial urinary sphincter (AUS) cuffs vs larger cuffs amongst men with stress urinary incontinence (SUI), with and without a history of pelvic radiotherapy (RT). PATIENTS AND METHODS: We reviewed the records of all men who underwent AUS placement by a single surgeon between September 2009 and June 2017 at our tertiary urban medical centre. A uniform perineal approach was used to ensure cuff placement around the most proximal corpus spongiosum after precise spongiosal measurement. Patients were stratified by cuff size and RT status, and patient demographics and surgical outcomes were analysed. Cases of AUS revision in which a new cuff was not placed were excluded. Success was defined as patient-reported pad use of ≤1 pad/day. RESULTS: Amongst 410 cases included in the analysis, the 3.5-cm cuff was used in 166 (40.5%), whilst 244 (59.5%) received larger cuffs (≥4.0 cm). Over a median follow-up of 50 months, there was AUS cuff erosion in 44 patients at a rate nearly identical in the 3.5-cm cuff (10.8%, 18/166) and the ≥4-cm cuff groups (10.7%, 26/244, P = 0.7). On multivariate logistic regression, clinical factors associated with AUS cuff erosion included a history of pelvic RT, prior AUS cuff erosion, prior urethroplasty, and a history of inflatable penile prosthesis (IPP) placement. Patient demographics were similar between the cuff-size groups; including age, body mass index, comorbidities, smoking history, RT history, prior AUS, and prior IPP placement. Continence rates were high amongst all AUS patients, with similar success in both groups (82% for 3.5-cm cuff, 90% for ≥4-cm cuff, P = 0.1). CONCLUSIONS: After 8 years of experience and extended follow-up, the outcomes of the 3.5-cm AUS cuff appear to be similar to ≥4-cm cuffs for effectiveness and rates of urethral erosion. RT patients have a higher risk of cuff erosion regardless of cuff size.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. McKibben MJ, Shakir N, Fuchs JS, et al. Erosion rates of 3.5-cm artificial urinary sphincter cuffs are similar to larger cuffs. BJU Int. 2018. PMID: 30007096. doi:10.1111/bju.14483

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。