人工尿道括约肌袖套置入时保留背外侧纤维肌肉组织与低感染和侵蚀率相关
结果显示无感染发生,总体侵蚀率为2.9%,自发性侵蚀率为0.9%,1年社会控尿率为74%,表明该改良技术在高危人群中安全且感染和侵蚀率低。
要点
- 改良AUS置入技术保留背外侧纤维肌肉组织并横向切断腹侧球海绵体肌。
- 208例高危患者中无感染发生,总体侵蚀率2.9%,自发性侵蚀率0.9%。
- 1年社会控尿率74%,因任何原因再手术概率7%。
核心结论
- AUS置入时保留背外侧纤维肌肉组织是降低侵蚀风险的有效方法。
- 该改良技术在高危人群中安全,感染和侵蚀率低,同时维持良好功能结局。
研究设计与样本
- 共纳入208例患者,记录术前放疗和膀胱颈挛缩等变量及随访中的有效性、感染、侵蚀和再手术情况。
主要发现
- 40%患者有放疗史,其中15%曾接受挽救性根治性前列腺切除术;26%有既往膀胱颈挛缩。
- 无患者发生感染;总体侵蚀6例(2.9%),自发性侵蚀2例(0.9%)。
- 21例患者因装置故障接受再手术;1年内因任何原因再手术的概率为7%(95%CI 4-12%)。
- 1年社会控尿率为74%(95%CI 67-81%)。
临床怎么用
- 在AUS袖套置入中可考虑保留尿道球部背外侧纤维肌肉组织并横向切断腹侧球海绵体肌,以降低感染和侵蚀风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To present a modified technique in artificial urinary sphincter (AUS) placement that is associated with low rates of erosion and infection in a high-risk population. PATIENTS AND METHODS: After Institutional Review Board approval, we identified patients who underwent primary AUS placement using the modified technique between January 2007 and November 2015. Our modification consists of preserving the dorsolateral fibromuscular tissue surrounding the bulbar urethra and horizontally transecting the ventral bulbospongiosus muscle during urethral cuff placement. Preoperative variables such as radiotherapy (RT) and bladder neck contractures were recorded. Effectiveness and complications including infections, erosions, and re-operations were recorded at follow-up. RESULTS: The new technique was used on 208 patients: 40% had a history of RT, including 15% who had had a salvage radical prostatectomy; 26% had had previous bladder neck contractures. No patients developed infection. Overall, erosion occurred in six (2.9%) patients and spontaneous erosions occurred in two (0.9%) during the study period. In all, 21 patients underwent re-operation for device failure. The probability of re-operation for 'any' reason was 7% (95% confidence interval [CI] 4-12%) at 1 year. The 1-year social continence rate was 74% (95% CI 67-81%). CONCLUSION: Preservation of dorsolateral fibromuscular tissue during AUS placement is an effective means to achieve a low risk of erosions. Our modified technique is safe with low infection and erosion rates, whilst maintaining good functional outcomes despite a high-risk population.
引用
- Cheung F, Fathollahi A, Vertosick E, et al. Dorsolateral fibromuscular tissue preservation during artificial urinary sphincter cuff placement is associated with low infection and erosion rates. BJU Int. 2018. PMID: 29972627. doi:10.1111/bju.14476
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。