文献速递肾癌与肾肿瘤

机器人肾部分切除术中肾动脉支架患者的精准阻断技术

Precise Clamping of Renal Artery With Endovascular Stents During Robotic Partial Nephrectomy: Technical Hints to Optimize Outcomes.
PubMed 文献 · Urology · 2018-04-25

本文描述了对既往置入肾动脉内支架的患者行机器人肾部分切除术时精准阻断肾动脉的技术要点。研究回顾了3例患者,其中一例为73岁左肾10cm肿瘤并主动脉腔内修复后开窗支架。关键技术包括术前CT规划、多平面容积渲染、支架远端精准阻断、细致游离肾蒂及术中多普勒超声确认血流。无中转开放,技术可行且可重复。

要点

  • 术前CT及多平面容积渲染有助于规划肾蒂游离和血管三维定位。
  • 肾动脉阻断需在支架远端进行,以避免支架闭塞。
  • 术中多普勒超声在松开阻断后确认肾动脉血流。

核心结论

  • 对肾动脉支架患者行肾部分切除术需在支架远端游离并阻断肾动脉,该技术可行、可重复且有助于优化结局。

研究设计与样本

  • 回顾性描述3例既往置入肾动脉内支架后行机器人肾部分切除术的患者,并展示一例73岁左肾10cm肿瘤伴主动脉开窗支架的病例视频。

主要发现

  • 3例患者中位年龄69.6岁,中位体重指数31.3,平均估算肾小球滤过率36.6 mL/min,无中转开放手术。
  • 关键技巧包括术前CT规划、多平面容积渲染、支架远端精准阻断、细致游离肾蒂及术中多普勒超声确认血流。

关键数值与推荐

  • 肾动脉阻断需在肾动脉支架远端进行以避免支架闭塞。
  • 术中多普勒超声在松开阻断后确认肾动脉血流通畅。

临床怎么用

  • 术前应完善CT及多平面容积渲染以规划肾蒂游离和血管定位。
  • 术中需广泛细致游离肾蒂,在支架远端精准阻断肾动脉,松开后以多普勒超声确认血流。

局限性

  • 样本量仅3例,为单中心回顾性描述,技术推广需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To describe our surgical technique for robotic partial nephrectomy,1 focusing on specific technical hints for vascular clamping on patients with renal masses and endovascular stent (ES) in the renal artery. METHODS: We reviewed the records of 3 patients that underwent robotic partial nephrectomy in our institution with precise clamping of renal arteries due to previous placement of ES. Perioperative outcomes were recorded. In our video, we present the case of 73-year-old Caucasian with a 10-cm left renal neoplasm and associated fenestrated endograft due to endovascular aorta repair. After preoperative imaging was reviewed, a robotic approach was planned. RESULTS: Key hints for outcomes optimization during nephron sparing surgery on patients with ES on the renal arteries: (1) preoperative computed tomography scan is crucial for surgical planning on dissection of the renal pedicle,2 (2) an additional multiplanar volume rendering of the computed tomography scan may allow better 3-dimensional visualization and orientation of the renal vasculature and anatomy, (3) precise renal artery clamping distal from the renal artery stent is required to avoid renal stent occlusion, (4) extensive and meticulous dissection of the renal pedicle is mandatory to dictate correct clamping, and (5) an intraoperative Doppler ultrasound after clamping release confirms the blood flow through the renal arteries.3 From the patients analyzed, median age was 69.6 years, median body mass index was 31.3, and mean estimated glomerular filtration rate was 36.6 mL/min. No cases were converted to open procedures. Perioperative outcomes are described in Table 1. CONCLUSION: Partial nephrectomy in patients with renal artery stents requires distal dissection of the renal artery beyond the stent. Our described technique provides feasible, reproducible, and valuable surgical suggestions for outcomes optimization during nephron-sparing surgery on patients with endovascular graft stents.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Garisto JD, Dagenais J, Nyame Y, et al. Precise Clamping of Renal Artery With Endovascular Stents During Robotic Partial Nephrectomy: Technical Hints to Optimize Outcomes. Urology. 2018. PMID: 29704583. doi:10.1016/j.urology.2018.03.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。