文献速递前列腺癌

经直肠剪切波弹性成像评估临床局限性前列腺癌的性能特征:一项前瞻性研究

Performance Characteristics of Transrectal Shear Wave Elastography Imaging in the Evaluation of Clinically Localized Prostate Cancer: A Prospective Study.
PubMed 文献 · J Urol · 2018-03-30

该前瞻性诊断准确性研究纳入212例接受腹腔镜根治性前列腺切除术的临床局限性前列腺癌患者,术前经直肠剪切波弹性成像定量测量前列腺硬度并与三维打印模具辅助的全标本病理对比。恶性区域硬度显著高于良性区域, cutoff 82.6 kPa时敏感度96.8%、特异度67.8%(p<0.01),不同Gleason分级间杨氏模量差异显著(p<0.05),并可检测包膜突破预测病理分期。

要点

  • 经直肠剪切波弹性成像可准确检出前列腺癌灶,cutoff 82.6 kPa时敏感度96.8%、特异度67.8%。
  • 不同Gleason分级肿瘤硬度差异显著,低、中、高级别分别为91.6、102.3、131.8 kPa。
  • 该技术可检测包膜突破并显著预测前列腺癌病理分期。

核心结论

  • 经直肠定量剪切波弹性成像可准确检测前列腺癌灶并区分癌与良性组织。
  • 该技术可可靠地表型前列腺癌侵袭性。

研究设计与样本

  • 前瞻性、方案驱动的诊断准确性研究,连续纳入212例因临床局限性前列腺癌接受腹腔镜根治性前列腺切除术的男性。
  • 术前使用腔内经直肠探头获取前列腺定量硬度数据,并与基于三维打印模具技术的根治标本详细病理检查对比。

主要发现

  • 恶性区域定量硬度(kPa)显著高于良性区域。
  • cutoff 82.6 kPa时,剪切波弹性成像的敏感度和特异度分别为96.8%和67.8%(p<0.01)。
  • 不同肿瘤分级间杨氏模量差异显著:低级别(Gleason评分6)91.6 kPa、中级别(Gleason评分7)102.3 kPa、高级别(Gleason评分8或以上)131.8 kPa(p<0.05)。
  • 剪切波弹性成像可检测包膜突破,并显著预测前列腺癌病理分期。

临床怎么用

  • 经直肠剪切波弹性成像可作为术前评估前列腺癌灶及侵袭性的无创影像工具。
  • 定量硬度值有助于区分癌与良性组织,并可辅助预测肿瘤分级和病理分期。

局限性

  • 存在选择偏倚。
  • 研究为单中心。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We tested the diagnostic accuracy of shear wave elastography to detect and phenotypically characterize prostate cancer compared with whole mount radical prostatectomy histopathology. MATERIALS AND METHODS: In this prospective, protocol driven, diagnostic accuracy study 212 consecutive men undergoing laparoscopic radical prostatectomy for clinically localized prostate cancer were recruited. Quantitative stiffness data on the prostate gland were obtained in each patient using an endocavitary transrectal transducer before laparoscopic radical prostatectomy. Those data were compared with a detailed histopathological examination of the radical prostatectomy specimen using 3-dimensional printing mold based technology to ensure an improved image histology orientation. ROC curves were assessed between the groups. RESULTS: Quantitative stiffness data estimated in kPa were significantly higher in malignant compared with benign areas. At a cutoff of 82.6 kPa the sensitivity and specificity of shear wave elastography were 96.8% and 67.8%, respectively (p <0.01). Significant differences were observed for different cancer grades with the Young moduli, including 91.6, 102.3 and 131.8 kPa for low grade (Gleason score 6), intermediate grade (Gleason score 7) and high grade (Gleason score 8 or greater) prostate cancer, respectively (p <0.05). Shear wave elastography also detected capsular breaches with significant prediction of prostate cancer pathological staging. Potential limitations include selection bias and study being single center site. CONCLUSIONS: Quantitative shear wave elastography via the transrectal approach accurately detected cancer foci and revealed significant differences between cancerous and benign tissue. Moreover, this technique can be used to reliably phenotype prostate cancer aggressiveness.

来源:J Urol,查看原文。版权归原作者所有。

引用

  1. Wei C, Li C, Szewczyk-Bieda M, et al. Performance Characteristics of Transrectal Shear Wave Elastography Imaging in the Evaluation of Clinically Localized Prostate Cancer: A Prospective Study. J Urol. 2018. PMID: 29605444. doi:10.1016/j.juro.2018.03.116

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。