超声在腹腔镜肾盂成形术中确认顺行输尿管支架置入的应用
本文描述了一种在腹腔镜肾盂成形术中利用术中膀胱超声确认顺行放置输尿管支架远端位置的技术。该方法无需改变患者体位或使用膀胱镜,在8例腹腔镜肾盂成形术中成功实施,无失败病例。超声可能比观察支架置入后膀胱输尿管反流更敏感,可避免支架错位及膀胱内染料使用。
要点
- 腹腔镜肾盂成形术中顺行置入输尿管支架后,用膀胱超声确认远端卷曲在膀胱内。
- 该技术避免术中改变体位行膀胱镜确认,在8例手术中均成功。
- 超声可能比观察反流更敏感,且避免染料染色组织影响手术平面。
核心结论
- 术中超声可成功确认成人腹腔镜离断性肾盂成形术中顺行输尿管支架的远端膀胱内位置。
研究设计与样本
- 技术描述性研究,在8例腹腔镜肾盂成形术中应用该超声确认技术。
主要发现
- 该技术在8例腹腔镜肾盂成形术中成功实施,无失败。
- 超声可识别膀胱腔内的支架远端卷曲,无需患者重新摆体位行膀胱镜。
- 超声可能比观察支架置入后膀胱输尿管反流更敏感,可防止支架错位。
关键数值与推荐
- 使用3向20-French Foley导管,膀胱逆行充盈300cc生理盐水。
- 经5-French交换导管和导丝顺行放置4.8-French、26-cm输尿管支架。
- 完成输尿管吻合后壁缝合后置入支架,近端卷曲置入肾盂后完成吻合。
临床怎么用
- 在腹腔镜肾盂成形术中顺行放置支架后,无需改变体位,行术中膀胱超声确认支架远端卷曲位于膀胱腔内。
局限性
- 本文未报告该技术在成人中的既往描述,仅提及在儿科已有描述。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To describe our ultrasound technique for confirming intraoperative, antegrade-placed ureteral stent position during laparoscopic pyeloplasty. BACKGROUND: Disadvantages of retrograde stent placement include the need to reposition the patient into and out of the lithotomy position. Antegrade stent placement can reduce procedure time but requires confirming appropriate distal placement into the bladder with cystoscopy, percutaneous drain placement, or instillation of methylthioninium chloride or indigo carmine. MATERIALS AND METHODS: A 3-way 20-French Foley catheter is placed after induction with general anesthesia. Laparoscopic transperitoneal dismembered pyeloplasty is performed. Intraoperatively, the bladder is filled retrograde with 300ccs normal saline. After completing the posterior suture line of the ureteral anastomosis, a 4.8-French, 26-cm ureteral stent is placed antegrade down the ureter using a 5-French exchange catheter and guidewire. The stent is passed over the guidewire into the bladder. The proximal curl is then placed into the renal pelvis and the anastomosis is completed. Without patient repositioning, an intraoperative bladder ultrasound is performed to identify the distal stent curl within the bladder lumen. RESULTS: This technique demonstrated that ultrasound can guide antegrade stent placement in adult, laparoscopic ureteral surgery. It eliminated the need for intraoperative repositioning of the patient for intraoperative cystoscopy to confirm stent placement and was performed successfully during 8 laparoscopic pyeloplasty cases without failure. Ultrasound is likely more sensitive compared with looking for the presence of vesicoureteral reflux after stent placement, prevents stent malposition, and avoids the use of intravesical dyes that upon reflux can stain tissues and obscure surgical planes. CONCLUSION: Here we demonstrate successful use of intraoperative ultrasound to confirm appropriate distal stent positioning in the bladder of an adult patient following antegrade stent placement for laparoscopic dismembered pyeloplasty. To our knowledge, this has been described in pediatrics, but never in adult patients.
引用
- Bayne DB, Usawachintachit M, Chi T, et al. Ultrasound for Intraoperative Confirmation of Antegrade Ureteral Stent Placement During Laparoscopic Pyeloplasty. Urology. 2018. PMID: 29305200. doi:10.1016/j.urology.2017.12.019