文献速递肾癌与肾肿瘤

手持光学相干断层扫描探头在肾部分切除术中评估手术切缘的可行性研究

Margin Assessment in Renal Surgery Using a Handheld Optical Coherence Tomography Probe.
PubMed 文献 · Urology · 2017-11-28

本研究评估手持光学相干断层扫描(OCT)探头在肾部分切除术(PN)中术中评估手术切缘的可行性。首先对1例9cm肿瘤的根治性肾切除标本进行19个切面(0mm、1mm、2mm大体切缘)的离体OCT测距,随后对15例PN肿瘤标本进行离体OCT评估切缘状态并测量肿瘤与肾实质的衰减系数。OCT对阳性切缘的识别敏感性和特异性均为100%,在PN标本中正确判定所有标本切缘阴性(P<.0001)。

要点

  • 手持OCT探头可在离体条件下评估肾部分切除术切缘。
  • 对大体0mm、1mm、2mm切缘,OCT测得中位切缘宽度分别为0mm、0.9mm、2.7mm。
  • OCT识别阳性切缘的敏感性和特异性均为100%。

核心结论

  • 手持OCT探头在PN离体条件下评估切缘具有可行性,可能减少术中冰冻切片需求并有助于减少肾实质切除。

研究设计与样本

  • 初步可行性研究:将1例含9cm肿瘤的根治性肾切除标本切成19个切面,暴露0mm(n=8)、1mm(n=6)、2mm(n=5)大体切缘,用OCT测定各标本切缘宽度。
  • 前瞻性离体评估:对15例PN肿瘤标本用OCT判定切缘状态并测量肿瘤与肾实质的衰减系数。

主要发现

  • 大体0mm(阳性)、1mm、2mm切缘的中位OCT切缘宽度分别为0mm、0.9mm(范围0.7-2.9mm)、2.7mm(范围1.65-2.8mm)。
  • 所有切缘组间测量差异有统计学意义(P<.04)。
  • OCT识别阳性切缘的敏感性和特异性均为100%。
  • 在PN标本中,OCT正确判定所有标本切缘阴性(P<.0001)。

临床怎么用

  • OCT可能减少术中冰冻切片的需求并有助于减少肾实质切除。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the use of a handheld optical coherence tomography (OCT) probe for the evaluation of intraoperative surgical margins during partial nephrectomy (PN). METHODS: In an initial feasibility study, a radical nephrectomy specimen with a 9-cm tumor was cut into 19 sections, exposing 0 mm (n = 8), 1 mm (n = 6), and 2 mm (n = 5) gross margins. OCT was used to determine the margin width in each specimen. Second, a prospective ex vivo assessment of 15 PN tumor specimens was performed with OCT to determine margin status and to measure the attenuation coefficient of tumor and renal parenchyma. RESULTS: Median OCT margin width measurements for sectioned samples were 0 mm, 0.9 mm (range 0.7-2.9 mm), and 2.7 (range 1.65-2.8 mm) for grossly 0 mm (positive), 1 mm, and 2 mm margins, respectively. The difference between measurements from all margin groups was statistically significant (P <.04). The sensitivity and specificity for identifying positive margins were both 100%. In the PN specimens, OCT correctly found that all specimens had negative margins (within <.0001). CONCLUSION: We have demonstrated the feasibility of using a handheld OCT probe to assess margins ex vivo during PN. OCT may reduce the need for intraoperative frozen section and aid in minimizing parenchymal excision.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Ludwig WW, Wobker SE, Ball MW, et al. Margin Assessment in Renal Surgery Using a Handheld Optical Coherence Tomography Probe. Urology. 2017. PMID: 29196067. doi:10.1016/j.urology.2017.11.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。