人工尿道括约肌置入前后辅助放疗的多机构回顾性比较
该多机构回顾性研究纳入1987至2016年间接受人工尿道括约肌(AUS)置入和放疗的前列腺癌男性306例,比较放疗在AUS置入前(组1,292例,95.4%)与置入后(组2,14例,4.6%)的并发症率、翻修率和每日尿垫数;结果显示放疗时机似乎不显著影响并发症率或尿控(以尿垫数衡量),AUS置入后放疗显示初步安全性和可行性。
要点
- 组1侵蚀32/292(11.0%)vs 组2 0/14(0.0%)(P = .191)。
- 组1翻修91/292(31.2%)vs 组2 2/14(14.3%)(P = .180)。
- 两组术后日均尿垫数无显著差异(P = .907),各自术前术后均显著减少(P < .001)。
核心结论
- 放疗时机似乎不显著影响AUS置入后的并发症率或尿控(以尿垫数衡量)。
- 该多机构回顾性分析显示AUS置入后放疗的侵蚀率和翻修率相似,并证明AUS置入后放疗的初步安全性和可行性。
研究设计与样本
- 多机构回顾性分析,纳入1987至2016年间接受AUS置入和放疗的前列腺癌男性306例。
- 组1为放疗在AUS置入前(292例,95.4%),组2为放疗在AUS置入后(14例,4.6%)。
- AUS置入后中位随访30个月。
主要发现
- 组1侵蚀32/292(11.0%)vs 组2 0/14(0.0%)(P = .191)。
- 组2无感染或机械故障患者。
- 组1翻修91/292(31.2%)vs 组2 2/14(14.3%)(P = .180)。
- 组1每日尿垫数AUS置入前5.24 ± 3.12 vs 置入后1.13 ± 1.31(P < .001)。
- 组2每日尿垫数AUS置入前6.09 ± 1.97 vs 置入后1.53 ± 0.99(P < .001);两组术后日均尿垫数无显著差异(P = .907)。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To determine if the timing of radiation therapy on artificial urinary sphincter (AUS) impacts complication rates, revision rates, and number of pads per day after placement. METHODS: A retrospective review was conducted of men with prostate cancer who underwent AUS placement and radiation therapy between 1987 and 2016. RESULTS: Of 306 men, 292 (95.4%) received radiation before AUS placement (group 1) and 14 (4.6%) received radiation after AUS placement (group 2). Median follow-up was 30 months after AUS placement. Group 1 had 32 of 292 (11.0%) patients suffer from erosion, compared with 0 of 14 (0.0%) patients in group 2 (P = .191). None of the patients in group 2 had infection or mechanical failure. The number of patients who received revision in group 1 was 91 of 292 (31.2%) and in group 2 was 2 of 14 (14.3%) (P = .180). The number of pads used per day in group 1 before and after AUS placement was 5.24 ± 3.12 and 1.13 ± 1.31, respectively (P <.001). In group 2, the number of pads used per day before and after AUS placement was 6.09 ± 1.97 and 1.53 ± 0.99, respectively (P <.001). There was no significant difference in the average number of postoperative pads used per day between group 1 and group 2 (P = .907). CONCLUSION: The timing of radiation therapy does not appear to significantly affect complication rates or urinary continence, as measured in pads used after AUS placement. This multi-institutional retrospective analysis showed similar erosion and revision rates when radiation occurred after AUS placement and demonstrates preliminary safety and feasibility of the administration of radiation after AUS placement.
引用
- DeLay KJ, Haney NM, Chiang J, et al. Comparison of Adjuvant Radiation Therapy Before or After Artificial Urinary Sphincter Placement: A Multi-Institutional, Retrospective Analysis. Urology. 2017. PMID: 29223493. doi:10.1016/j.urology.2017.11.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。