文献速递前列腺癌

64铜前列腺特异性膜抗原正电子发射断层扫描/计算机断层扫描对中高危前列腺癌原发淋巴结分期的诊断准确性:我们的初步经验

Diagnostic Accuracy of 64Copper Prostate-specific Membrane Antigen Positron Emission Tomography/Computed Tomography for Primary Lymph Node Staging of Intermediate- to High-risk Prostate Cancer: Our Preliminary Experience.
PubMed 文献 · Urology · 2017-04-21

本研究为观察性前瞻性研究,纳入23例中高危前列腺癌患者,术前接受64Cu-PSMA PET/CT分期后行腹腔镜根治性前列腺切除及扩大盆腔淋巴结清扫。以病理为参考,患者水平分析显示灵敏度87.5%、特异度100%、阳性预测值100%、阴性预测值93.7%,4小时SUVmax与Gleason评分、指数及累积肿瘤体积呈显著正相关。

要点

  • 64Cu-PSMA PET/CT对中高危前列腺癌原发淋巴结分期具有高诊断准确性。
  • 患者水平灵敏度87.5%、特异度100%、阳性预测值100%、阴性预测值93.7%。
  • 4小时SUVmax与Gleason评分、指数及累积肿瘤体积呈显著正相关。

核心结论

  • 在中高危前列腺癌研究队列中,64Cu-PSMA PET/CT对根治性前列腺切除术前原发淋巴结分期显示出高诊断准确性。

研究设计与样本

  • 观察性前瞻性研究,纳入23例中高危前列腺癌患者,术前行64Cu-PSMA PET/CT局部及淋巴结分期,随后行腹腔镜根治性前列腺切除加扩大盆腔淋巴结清扫。
  • 以最终病理结果为参考,计算64Cu-PSMA PET/CT对淋巴结状态的灵敏度、特异度、阳性预测值和阴性预测值。
  • 评估前列腺内肿瘤范围及分级与64Cu-PSMA前列腺内分布的相关性。

主要发现

  • 研究队列共获取413枚淋巴结,病理分析发现8例(35%)患者共22枚淋巴结转移,占23例患者的5%。
  • 患者水平分析显示,以4小时SUVmax为参考,64Cu-PSMA PET/CT在8例淋巴结阳性患者中7例(22%)为阳性,灵敏度87.5%、特异度100%、阳性预测值100%、阴性预测值93.7%。
  • 受试者工作特征曲线下面积为0.938。
  • 4小时SUVmax与Gleason评分、指数及累积肿瘤体积呈显著正相关。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the diagnostic accuracy of 64Copper prostate-specific membrane antigen (64Cu-PSMA) positron emission tomography/computed tomography (PET/CT) in the primary lymph node (LN) staging of a selected cohort of intermediate- to high-risk prostate cancer (PCa) patients. MATERIALS AND METHODS: An observational prospective study was performed in 23 patients with intermediate- to high-risk PCa, who underwent 64Cu-PSMA PET/CT for local and lymph nodal staging before laparoscopic radical prostatectomy with an extended pelvic LN dissection. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for LN status of 64Cu-PSMA PET/CT were calculated using the final pathological findings as reference. Furthermore, we evaluated the correlation of intraprostatic tumor extent and grading with 64Cu-PSMA intraprostatic distribution. RESULTS: Pathological analysis of LN involvement in 413 LNs harvested from our study cohort identified a total of 22 LN metastases in 8 (5%) of the 23 (35%) PCa patients. Imaging-based LN staging in a per-patient analysis showed that 64Cu-PSMA PET/CT was positive in 7 of 8 LN-positive patients (22%) with a sensitivity of 87.5%, specificity of 100%, PPV of 100%, and NPV of 93.7%, considering the maximum standardized uptake value (SUVmax) at 4 hours as our reference. Receiver operating characteristic curve was characterized by an area under the curve of 0.938. A significant positive association was observed between SUVmax at 4 hours with Gleason score, index, and cumulative tumor volume. CONCLUSION: In our intermediate- to high-risk PCa patients study cohort, we showed the high diagnostic accuracy of 64Cu-PSMA PET/CT for primary LN staging before radical prostatectomy.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Cantiello F, Gangemi V, Cascini GL, et al. Diagnostic Accuracy of 64Copper Prostate-specific Membrane Antigen Positron Emission Tomography/Computed Tomography for Primary Lymph Node Staging of Intermediate- to High-risk Prostate Cancer: Our Preliminary Experience. Urology. 2017. PMID: 28438628. doi:10.1016/j.urology.2017.04.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。