文献速递泌尿系结石

非接触式钬激光碎石爆米花技术的最佳参数设置

Optimal Settings for the Noncontact Holmium:YAG Stone Fragmentation Popcorn Technique.
PubMed 文献 · J Urol · 2017-04-23

该体外研究用4枚人工结石评估爆米花技术,测试0.5至1.5 J、10至20及40 Hz、长短脉冲、273与365 μm光纤组合,共144次试验,以结石体积减少50%为高效阈值。长脉冲、更长时间、273 μm光纤及更高功率是高效的显著预测因素。

要点

  • 以结石体积减少50%为高效阈值,长脉冲是高效的显著预测因素(OR 2.7,95%CI 1.05-7.15)。
  • 更长作用时间是高效的显著预测因素(OR 11.4,95%CI 3.88-33.29)。
  • 273 μm小光纤(OR 0.23,95%CI 0.08-0.70)及更高功率(OR 1.14,95%CI 1.09-1.20)是显著预测因素。

核心结论

  • 更高能量、更长脉冲、高于10 Hz的频率、更长作用时间及更小激光光纤预示爆米花技术减少结石体积更高效。

研究设计与样本

  • 系统体外评估,使用4枚人工结石置于收集管中,固定输尿管镜经输尿管通道鞘提供持续灌流,激光距底部1 mm。
  • 测试0.5至1.5 J、10至20及40 Hz、长与短脉冲的组合,作用2和4分钟,使用273和365 μm激光光纤,所有测试重复3次。
  • 实验前后称重结石以评估设置效率,共完成144次测试。

主要发现

  • 结石平均起始重量为0.23 gm,各组间一致。
  • 实验后重量差中位数为0.07 gm(范围0.01至0.24)。
  • 以结石体积减少50%为高效阈值,长脉冲OR 2.7(95%CI 1.05-7.15),更长作用时间OR 11.4(95%CI 3.88-33.29),273 μm激光光纤OR 0.23(95%CI 0.08-0.70),更高功率(W)OR 1.14(95%CI 1.09-1.20)。

关键数值与推荐

  • 高效爆米花技术的显著预测因素:长脉冲(OR 2.7,95%CI 1.05-7.15)、更长作用时间(OR 11.4,95%CI 3.88-33.29)、273 μm激光光纤(OR 0.23,95%CI 0.08-0.70)、更高功率(OR 1.14,95%CI 1.09-1.20)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to evaluate the popcorn technique using a wide range of holmium laser settings and fiber sizes in a systematic in vitro assessment. MATERIALS AND METHODS: Evaluations were done with 4 artificial stones in a collection tube. A fixed ureteroscope was inserted through a ureteral access sheath to provide constant irrigation flow and the laser was placed 1 mm from the bottom. Combinations of 0.5 to 1.5 J, 10 to 20 and 40 Hz, and long and short pulses were tested for 2 and 4 minutes. We used 273 and 365 μm laser fibers. All tests were repeated 3 times. The stones were weighed before and after the experiments to evaluate the setting efficiency. Significant predictors of a highly efficient technique were assessed. RESULTS: A total of 144 tests were performed. Mean starting weight of the stones was 0.23 gm, which was consistent among the groups. After the experiment the median weight difference was 0.07 gm (range 0.01 to 0.24). When designating a 50% reduction in stone volume as the threshold indicating high efficiency, the significant predictors of an efficient popcorn technique were a long pulse (OR 2.7, 95% CI 1.05-7.15), a longer duration (OR 11.4, 95% CI 3.88-33.29), a small (273 μm) laser fiber (OR 0.23, 95% CI 0.08-0.70) and higher power (W) (OR 1.14, 95% CI 1.09-1.20). CONCLUSIONS: Higher energy, a longer pulse, frequencies higher than 10 Hz, a longer duration and a smaller laser fiber predict a popcorn technique that is more efficient at reducing stone volume.

来源:J Urol,查看原文。版权归原作者所有。