文献速递前列腺增生与排尿功能障碍

颊黏膜移植物球部尿道成形术后常规尿道造影:初始尿道渗漏对手术成功率的影响

Routine Urethrography After Buccal Graft Bulbar Urethroplasty: The Impact of Initial Urethral Leak on Surgical Success.
PubMed 文献 · Urology · 2017-02-15

回顾91例2007至2015年行颊黏膜移植物球部尿道成形术患者,中位造影时间23天,31例初始造影有渗漏。中位随访11个月15例复发,1年时渗漏与失败无差异,但3级渗漏及长度≥1.03 cm与1年后更高复发率相关。

要点

  • 术后3周尿道造影渗漏与1年内狭窄复发无显著差异(P=.220)。
  • 3级渗漏者1年后复发率高于≤2级者(Kaplan-Meier曲线P=.031)。
  • 渗漏长度≥1.03 cm者1年后复发率高于<1.03 cm者(P=.044)。

核心结论

  • 术后3周尿道造影渗漏与短期失败无关联,但渗漏长度和宽度可能是1年以上复发的预测因素。

研究设计与样本

  • 回顾性分析2007至2015年91例行颊黏膜移植物球部尿道成形术患者,中位造影时间23天,失败定义为膀胱镜检狭窄复发。

主要发现

  • 91例中31例初始造影有渗漏,中位随访11个月,15例狭窄复发,其中6例初始造影有渗漏。
  • 随访至少1年者,1年失败率在有无渗漏(P=.220)、长度(P=1.000)、宽度(P=1.000)或分级(P=.823)间无差异。
  • Kaplan-Meier曲线显示3级渗漏者失败率高于≤2级者(P=.031),曲线约在1年时显著分离。
  • 渗漏长度≥1.03 cm者1年后失败率高于<1.03 cm者(P=.044)。

关键数值与推荐

  • 渗漏长度截断值1.03 cm、宽度截断值0.32 cm由受试者工作特征曲线计算得出。
  • 尿道造影分级0-3分:无渗漏0分,任何渗漏、长度≥1.03 cm、宽度≥0.32 cm各计1分。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To determine the long-term impact of extravasation at initial post-urethroplasty urethrogram, we present a novel classification system and report the association of leak severity with outcome. MATERIALS AND METHODS: A total of 91 patients underwent buccal graft urethroplasties of the bulbar urethra from 2007 to 2015. Median time to urethrogram was 23 days. All leaks were characterized by length and width. Cutoffs for length and width were calculated using receiver operating characteristic curves. Each urethrogram was graded 0-3 (0 = no leak) with 1 point given for any leak, length ≥1.03 cm, and width ≥0.32 cm. Failure was stricture recurrence on cystoscopy. One-year failures were compared using Fisher test. Kaplan-Meier curves were constructed to measure the impact of variables on recurrence. RESULTS: Mean age was 46.1 years. Of 91 urethroplasties, 31 had extravasation on initial imaging. With median follow-up of 11 months, 15 patients had stricture recurrence, 6 of whom had leak on initial urethrogram. For patients with at least 1 year of follow-up, there was no difference at 1 year for failures, as to any leak (P = .220), length (P = 1.000), width (P = 1.000), or grade (P = .823). Grade 3 was associated with higher failure rates compared with grades ≤2 using Kaplan-Meier curves (P = .031), with the curves significantly diverging around the 1-year mark. Similarly, length ≥1.03 cm was associated with higher failure rates compared with <1.03 cm beyond 1 year (P = .044). CONCLUSION: Although there is no indication that leaks at 3 weeks are associated with short-term failure, leak length and width appear to be a predictor of longer term recurrence (>1 year).

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Grossgold ET, Eswara JR, Siegel CL, et al. Routine Urethrography After Buccal Graft Bulbar Urethroplasty: The Impact of Initial Urethral Leak on Surgical Success. Urology. 2017. PMID: 28214570. doi:10.1016/j.urology.2017.02.015