多参数磁共振/超声融合前列腺穿刺活检:用于更好检出和表征指数肿瘤的穿刺针数与空间分布
研究纳入327例直肠指检阴性、既往标准穿刺阴性后因PSA升高和/或mpMRI可检出病灶行MRI/经直肠超声融合靶向穿刺的患者,按指数病灶直径≤8 mm或>8 mm分别取4或6针。166例(50.7%)检出前列腺癌;阳性针主要位于靶区中心;Gleason评分异质性在≤8 mm靶区为12.6%,>8 mm靶区为26.4%。作者认为单针穿刺可能不充分,靶区中心取2针可能提高检出并优化最高Gleason模式的发现。
要点
- 166/327例(50.7%)检出前列腺癌,其中指数病灶≤8 mm者79例(47.6%),>8 mm者87例(52.4%)。
- 阳性针主要分布于靶区中心;Gleason评分异质性≤8 mm靶区12.6% vs >8 mm靶区26.4%。
- 作者认为单针融合靶向穿刺可能不充分,靶区中心取2针可能更准确检出并优化最高Gleason模式发现。
核心结论
- 以单针行MRI/经直肠超声融合靶向穿刺可能不充分,靶区中心取2针可能提供更准确的癌检出并优化最高Gleason模式的发现机会。
研究设计与样本
- 327例直肠指检阴性、因PSA升高/上升和/或mpMRI可检出1个及以上病灶、既往标准穿刺阴性后行MRI/经直肠超声融合靶向穿刺的患者。
- 按每个指数病灶直径≤8 mm或>8 mm分别按既定顺序取4针或6针。
主要发现
- 166例(50.7%)检出前列腺癌,其中指数病灶≤8 mm者79例(47.6%),>8 mm者87例(52.4%)。
- 指数肿瘤≤8 mm者中阳性针数1、2、3、4针分别为7例(8.9%)、31例(39.2%)、27例(34.2%)、14例(17.7%)。
- 病灶>8 mm者中阳性针数1、2、3、4、5、6针分别为8例(9.2%)、30例(34.5%)、13例(14.9%)、14例(16.1%)、12例(13.8%)、10例(11.5%)。
- 阳性针主要见于靶区中心。
- Gleason评分异质性在≤8 mm靶区为12.6%,在>8 mm靶区为26.4%。
临床怎么用
- 作者认为单针融合靶向穿刺可能不充分,靶区中心取2针可能提高癌检出准确性并优化最高Gleason模式的发现。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We evaluated the minimum core number for better index tumor detection to determine the best core site as well as biopsy Gleason score heterogeneity in the same index lesion. The aim was to optimize the highest Gleason score detection. MATERIALS AND METHODS: A total of 327 patients with negative digital rectal examination underwent magnetic resonance imaging/transrectal ultrasound fusion targeted biopsy for elevated/rising prostate specific antigen and/or 1 or more detectable lesions on multiparametric magnetic resonance imaging after a previous negative standard biopsy. Depending on the diameter of each index lesion (8 or less, or greater than 8 mm) 4 or 6 cores, respectively, were taken according to a well determined sequence. RESULTS: Of the patients 166 (50.7%) had prostate cancer, including 79 (47.6%) with an 8 mm or less index lesion and 87 (52.4%) with a greater than 8 mm index lesion. Of patients with an index tumor 8 mm or less 7 (8.9%) had 1, 31 (39.2%) had 2, 27 (34.2%) had 3 and 14 (17.7%) had 4 positive cores. Similarly, of patients with a lesion greater than 8 mm 8 (9.2%) had 1, 30 (34.5%) had 2, 13 (14.9%) had 3, 14 (16.1%) had 4, 12 (13.8%) had 5 and 10 (11.5%) had 6 positive cores. The major prevalence of positive cores was observed in the center of the target. Gleason score heterogeneity was found in 12.6% of those with an 8 mm or less target vs 26.4% with a target greater than 8 mm. In the center of the target there was a slight prevalence of Gleason pattern 4 or greater, or a lesser pattern. CONCLUSIONS: Approaching magnetic resonance imaging/transrectal ultrasound fusion targeted biopsy with a single core might be inadequate. Rather, taking 2 cores in the center of the index lesion may provide more accurate cancer detection and optimize the chances of finding the highest Gleason pattern.
引用
- Porpiglia F, De Luca S, Passera R, et al. Multiparametric Magnetic Resonance/Ultrasound Fusion Prostate Biopsy: Number and Spatial Distribution of Cores for Better Index Tumor Detection and Characterization. J Urol. 2017. PMID: 28093292. doi:10.1016/j.juro.2017.01.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。