Stamey尿失禁评分系统在前列腺切除术后尿失禁评估中的聚合效度
结果显示Stamey分级与ICQ-Q-SF呈强正相关,与ICQ-Q-SF的一致性显著高于每日尿垫使用,且能反映患者恢复趋势。
要点
- Stamey分级与ICQ-Q-SF在各术后时间点均呈强正相关。
- Stamey分级与ICQ-Q-SF的一致性显著高于每日尿垫使用。
- 早期严重程度分级与后续恢复存在关联。
核心结论
- Stamey分级问卷结构更简单且一致性更高,可提高根治性前列腺切除术后随访效率并减少临床工作量。
主要发现
- 在735条不同时间点的数据记录中,Stamey分级与ICQ-Q-SF的相关系数为0.699、0.752、0.920、0.947(所有P<.001)。
- Bootstrap比较显示Stamey评分系统与ICQ-Q-SF的Kappa值为0.445、0.486、0.747、0.659,在所有术后时间点均显著高于每日尿垫使用(Kappa=0.054、0.017、0.188、0.214)(P<.001)。
- Stamey分级与患者恢复趋势相对应,早期严重程度分级与后续恢复之间存在关联。
临床怎么用
- Stamey分级可用于根治性前列腺切除术后尿失禁的随访评估,其问卷结构简单且与ICQ-Q-SF一致性较高。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To investigate the convergent validity of Stamey's Incontinence Scoring System, a simple tool, in assessing post-prostatectomy incontinence at different time points after surgery. METHODS: This was a retrospective study. Three hundred thirty-one patients who underwent radical prostatectomy at Beijing Hospital from January 2024 to May 2025 took part; 295 completed the study. Data of Stamey's Grade, ICI-Q-SF, and daily pad use at 1.5, 3, 6, and 12 months postoperatively were recorded. Spearman's rank correlation assessed the correlation between Stamey's grade and ICI-Q-SF. Quadratic weighted Kappa compared daily pad use and Stamey's grade for their agreement with ICI-Q-SF, with 4 severity levels defined according to guidelines. Bootstrap estimated the differences in Kappa coefficients. Trends in severity and recovery time across grades were evaluated. RESULTS: Across 735 data records at different time points, this system showed strong positive correlations with ICI-Q-SF (correlation coefficients = 0.699, 0.752, 0.920, 0.947; all P <.001). Bootstrap comparisons showed that the agreement of Stamey's Scoring System with ICI-Q-SF (Kappa = 0.445, 0.486, 0.747, 0.659) was significantly higher than that of daily pad use (Kappa = 0.054, 0.017, 0.188, 0.214) at all postoperative time points (P <.001). This system corresponded to the patients' recovery trend; there was an association between early severity grade and subsequent recovery. CONCLUSION: Compared with existing assessment tools, Stamey's grade has a simpler questionnaire structure and higher consistency. This can make follow-up for patients after radical prostatectomy more efficient and reduce clinical workload.
引用
- Shu C, Meng L, Zhang X, et al. Convergent Validity of Stamey's Incontinence Scoring System in Assessing Post-prostatectomy Urinary Incontinence. Urology. 2026. PMID: 42580420. doi:10.1016/j.urology.2026.07.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。