文献速递小儿泌尿与泌尿修复

吲哚菁绿荧光血管造影预测TIP尿道下裂修复中新尿道覆盖组织血流灌注的初步应用

Preliminary Use of Indocyanine Green Fluorescence Angiography in Predicting the Blood Perfusion of Neourethra Covering in TIP Hypospadias Repair.
PubMed 文献 · Urology · 2026-04-26

灌注不良组4例均出现腹侧坏死痂皮,3例(75%)发生瘘。结论认为ICG-FA是术中识别尿道下裂修复灌注缺陷的安全有效技术,灌注状态与术后并发症强相关。

要点

  • ICG-FA可术中半定量评估新尿道覆盖组织灌注,所有病例均清晰显像且无不良事件。
  • 灌注不良组4例均出现腹侧坏死痂皮,3例(75%)发生瘘。

核心结论

  • ICG-FA是术中识别尿道下裂修复灌注缺陷的安全有效技术。
  • ICG-FA判定的灌注状态与术后并发症强相关,为术中决策提供客观依据。

研究设计与样本

  • 使用SPY Elite系统进行标准化ICG-FA,按灰度荧光强度分为灌注良好组和灌注不良组。
  • 平均随访24个月(范围18-40个月),比较手术结局。

主要发现

  • 所有患者均行管状切开板(TIP)尿道成形术,ICG-FA所有病例均清晰显像且无不良事件。
  • 灌注不良组4例均出现腹侧坏死痂皮,3例(75%)发生瘘。

关键数值与推荐

  • 灌注良好定义为荧光强度与相邻组织匹配。
  • 灌注不良定义为荧光显著减弱。

临床怎么用

  • 术中可用ICG-FA半定量评估新尿道覆盖组织灌注,辅助判断是否需要调整覆盖组织。
  • 对ICG-FA提示灌注不良的区域应警惕术后坏死和瘘的风险,加强术后观察。

局限性

  • 随访时间平均24个月,范围18-40个月。
  • 单中心、非随机设计,结论需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the utility of indocyanine green fluorescence angiography (ICG-FA) for the semiquantitative assessment of perfusion in neourethral covering tissues. METHODS: Fourteen boys undergoing primary hypospadias repair between April and May 2021 were enrolled. Standardized ICG-FA was performed using the SPY Elite system. Tissue perfusion was categorized based on grayscale fluorescence intensity into 2 groups as follows: well perfused (fluorescence intensity matching adjacent tissues) and poorly perfused (markedly reduced fluorescence). Surgical outcomes were compared over a mean follow-up period of 24 months (range, 18-40 months). RESULTS: All patients underwent tubularized incised plate (TIP) urethroplasty. ICG-FA provided clear visualization in all cases, with no adverse events observed. Among the ten patients in the well-perfused group, no evidence of tissue necrosis or urethrocutaneous fistulas occurred; one case of glans dehiscence was noted. In contrast, all 4 patients in the poorly perfused group developed ventral necrotic crusts, and 3 (75%) developed fistulas. CONCLUSION: ICG-FA is a safe and effective technique for intraoperative identification of perfusion deficits in hypospadias repair. Perfusion status, as determined by ICG-FA, was strongly associated with postoperative complications, providing an objective basis to guide intraoperative decision-making.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Wang Y, Du G, Guo F, et al. Preliminary Use of Indocyanine Green Fluorescence Angiography in Predicting the Blood Perfusion of Neourethra Covering in TIP Hypospadias Repair. Urology. 2026. PMID: 42049142. doi:10.1016/j.urology.2026.04.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。