文献速递前列腺癌

荧光共聚焦显微镜在微创根治性前列腺切除术中评估手术切缘的研究

Margin evaluation with fluorescence confocal microscopy during minimally invasive radical prostatectomy.
PubMed 文献 · BJU Int · 2026-03-31

这项单中心前瞻性非随机试验纳入100例接受微创根治性前列腺切除术的患者,术中采用荧光共聚焦显微镜(FCM)分析前列腺后外侧切缘,并与最终解剖病理(AP)比较诊断准确性及两位泌尿病理学家间的一致性。结果显示FCM在患者水平敏感度65.5%、特异度80.2%,切缘水平敏感度60.5%、特异度91.3%,观察者间一致性分别为0.64和0.61。FCM可行且不扭曲最终AP。

要点

  • FCM术中评估切缘可行,患者水平敏感度65.5%、特异度80.2%。
  • 切缘水平FCM特异度达91.3%,阴性预测值90.7%。
  • 两位病理学家间一致性患者水平为0.64、切缘水平为0.61。

核心结论

  • 荧光共聚焦显微镜是根治性前列腺切除术中可行的技术,诊断准确性良好且不扭曲最终解剖病理。

研究设计与样本

  • 单中心前瞻性非随机试验(C2021/32),2022年1月至2023年2月连续纳入100例患者,共200个手术切缘。
  • 使用VivaScope® 2500M-G4激光扫描显微镜,术后由两位专家泌尿病理学家独立评估FCM图像。

主要发现

  • FCM阳性切缘37个(33例患者),最终病理阳性38个标本(29例患者)。
  • 患者水平FCM敏感度65.5%、特异度80.2%、阳性预测值57.5%、阴性预测值85.0%。
  • 切缘水平FCM敏感度60.5%、特异度91.3%、阳性预测值62.1%、阴性预测值90.7%。
  • 观察者间一致性(Cohen kappa)患者水平0.64、切缘水平0.61。

临床怎么用

  • 可在根治性前列腺切除术中采用FCM快速评估后外侧切缘,辅助术中决策。
  • FCM高特异度和阴性预测值有助于排除切缘阳性,但敏感度中等需结合最终病理确认。

局限性

  • 单中心、前瞻性非随机设计,样本量100例。
  • 仅分析后外侧切缘,未覆盖其他切缘部位。
  • 诊断准确性依赖专家病理学家判读,观察者间一致性中等。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To demonstrate the reliability and diagnostic accuracy of fluorescence confocal microscopy (FCM) analysis of surgical margins during minimally invasive radical prostatectomy (RP). PATIENTS AND METHODS: From January 2022 to February 2023, we enrolled 100 consecutive patients in this single-centre, prospective, non-randomised trial (C2021/32). The VivaScope® 2500M-G4 microscope (Mavig GmbH, Munich, Germany), a laser scanning microscope designed for rapid acquisition of high-resolution digital images, was employed. Following surgery, each posterolateral prostatic margin was analysed using FCM and reviewed by two expert urological pathologists. This study aimed to assess the accuracy of FCM in evaluating surgical margins during RP, comparing the diagnostic accuracy of FCM to final anatomical pathology (AP) and assessing the inter-rater agreement between two urological pathologists (Cohen's kappa agreement). RESULTS: A total of 100 patients (i.e., 200 surgical margins) were included. Overall, 37 margins in 33 patients were positive according to FCM. At final pathology, 38 specimens in 29 patients were positive. On a per-patient analysis sensitivity, specificity, positive predictive value, and negative predictive value of FCM were 65.5%, 80.2%, 57.5%, and 85.0%, respectively. On a per-margin analysis, they were 60.5%, 91.3%, 62.1%, and 90.7%, respectively. The inter-rater agreement was 0.64 and 0.61 for per-patient and per-margin analysis, respectively. CONCLUSIONS: Fluorescence confocal microscopy is a feasible technology to be employed during RP, offering a good diagnostic accuracy without distorting final AP.

来源:BJU Int,查看原文。版权归原作者所有。