文献速递小儿泌尿与泌尿修复泌尿系感染

彩色多普勒超声输尿管喷尿角与膀胱输尿管反流临床结局的关联

Association Between Ureteral Jet Angle by Color Doppler Ultrasonography and the Clinical Outcomes of Vesicoureteral Reflux.
PubMed 文献 · J Urol · 2026-02-17

本研究先在19名健康成人中验证输尿管喷尿角(UJA)测量的可靠性(组内相关系数0.90),再回顾209例因发热性尿路感染就诊并同时接受排尿性膀胱尿道造影和UJA测量的儿童。UJA在多次尿路感染、突破性感染和需手术患者中更高,在反流降级和缓解组中更低,提示其与VUR分级、感染发生及反流改善相关。

要点

  • UJA测量不受性别和侧别影响,与膀胱容量仅极弱正相关,组内相关系数0.90。
  • 多次尿路感染患者UJA(73.8°±2.1°)高于单次感染者(67.8°±1.9°,P=.036)。
  • UJA在突破性感染和手术患者中更高,在反流降级和缓解组中更低。

核心结论

  • 彩色多普勒超声测量UJA不仅与VUR分级相关,还与尿路感染发生和VUR改善相关,支持其在VUR管理中的作用。

研究设计与样本

  • 前瞻性信度研究纳入19名健康成人志愿者评估UJA测量可靠性。
  • 回顾性研究纳入209例因发热性尿路感染就诊并接受排尿性膀胱尿道造影和UJA测量的儿童患者。

主要发现

  • UJA不受性别或侧别影响,与膀胱容量呈极弱正相关,组内相关系数(2,1)为0.90。
  • 多次尿路感染患者UJA为73.8°±2.1°,高于单次感染者的67.8°±1.9°(P=.036)。
  • 突破性尿路感染患者UJA更高(P=.013)。
  • VUR降级组(P<.001)和缓解组(P<.001)UJA显著更低。
  • 接受手术干预的患者UJA显著高于非手术患者(P<.001)。

临床怎么用

  • UJA可作为无创超声指标辅助评估VUR患儿的尿路感染风险和反流转归。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Vesicoureteral reflux (VUR) is one of the common abnormalities in pediatric urology. We previously demonstrated that the ureteral jet angle (UJA) is a useful noninvasive screening tool for detecting high-grade VUR. To further explore its clinical application, we evaluated the association of UJA with UTI development and VUR improvement. MATERIALS AND METHODS: We assessed the reliability of the UJA measurement in 19 healthy adult volunteers in a prospective interrater reliability study. A retrospective study was conducted in 209 pediatric patients who presented with febrile UTI and underwent both voiding cystourethrography and UJA measurement. RESULTS: The UJA was unaffected by sex or laterality, showed a very weak positive correlation with bladder volume, and interrater reliability was high [intraclass correlation coefficient(2,1): 0.90]. The UJA was significantly higher in patients with multiple UTIs (73.8° ± 2.1°) than in those with a single episode (67.8° ± 1.9°, P = .036). It was also higher in patients with breakthrough UTI (P = .013). By contrast, it was significantly lower in the group with VUR downgrading (P < .001) and resolution (P < .001). Patients who underwent surgical intervention had a significantly higher UJA than nonsurgical patients did (P < .001). CONCLUSIONS: Measuring the UJA using color Doppler ultrasonography appears to be associated not only with VUR grade but also with UTI development and VUR improvement, supporting its role in VUR management.

来源:J Urol,查看原文。版权归原作者所有。

引用

  1. Iwasa S, Asanuma H, Ishikawa H, et al. Association Between Ureteral Jet Angle by Color Doppler Ultrasonography and the Clinical Outcomes of Vesicoureteral Reflux. J Urol. 2026. PMID: 41701951. doi:10.1097/JU.0000000000005000

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。