文献速递膀胱癌与上尿路尿路上皮癌

共聚焦荧光显微镜在膀胱肿瘤电切术中评估逼尿肌的可行性

Intraoperative evaluation of detrusor muscle during transurethral resection of bladder tumour using confocal fluorescent microscopy.
PubMed 文献 · BJU Int · 2026-02-11

该前瞻性研究纳入17例患者的36份标本,术中采用共聚焦荧光显微镜(CFM)评估经尿道膀胱肿瘤电切术(TURBT)标本中逼尿肌的存在。所有标本制备与CFM扫描均在5分钟内完成,两位病理专家阅片间一致性为91.7%。与最终组织病理学相比,专家病理阅片者使用CFM的灵敏度为87.5%、特异度为90%、阳性预测值为87.5%、阴性预测值为90%。

要点

  • CFM可在5分钟内完成术中标本评估,操作可行。
  • 病理专家CFM诊断灵敏度87.5%、特异度90%。
  • 泌尿外科受训者经培训后特异度达100%,灵敏度61.9%。

核心结论

  • CFM是TURBT标本切除质量实时术中评估的可行且有前景的辅助工具。
  • 专家病理阅片者诊断性能更优,但受训者经培训后也可达到可接受的准确度。
  • 仍需更大规模多中心研究验证并明确CFM的安全实施方式。

研究设计与样本

  • 前瞻性收集17例患者的36份TURBT标本。
  • 术中采用CFM分析切除面以评估逼尿肌存在。
  • CFM图像由两名委员会认证的泌尿生殖病理学家和两名完成CFM培训的泌尿外科受训者独立审阅。

主要发现

  • 所有标本制备与CFM扫描均在5分钟内完成。
  • 两位病理审阅者间一致性为91.7%。
  • 与最终组织病理学相比,专家病理阅片者CFM灵敏度87.5%、特异度90%、阳性预测值87.5%、阴性预测值90%。
  • 泌尿外科受训者CFM灵敏度61.9%、特异度100%、阳性预测值100%、阴性预测值66.7%。
  • 标准膀胱镜评估的灵敏度、特异度、阳性预测值、阴性预测值分别为100%、50%、71.4%、100%。

临床怎么用

  • CFM可作为TURBT术中实时评估标本是否含逼尿肌的辅助手段。
  • 经必要培训的泌尿外科受训者也可使用CFM获得可接受的特异度。

局限性

  • 样本量较小(17例患者、36份标本)。
  • 需要更大规模多中心研究验证 findings。
  • CFM在当代膀胱癌诊断与手术管理中的安全实施方式尚待明确。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate the feasibility of confocal fluorescence microscopy (CFM) for identifying detrusor muscle presence during transurethral resection of bladder tumour (TURBT). PATIENTS AND METHODS: A total of 36 specimens from 17 patients were prospectively collected. The resected surfaces were analysed intraoperatively using CFM to evaluate the presence of detrusor muscle. All CFM images were independently reviewed by two board-certified genitourinary pathologists and two urology trainees, who have completed the necessary CFM training. Interobserver agreement was assessed, and diagnostic concordance between the CFM interpretations, standard cystoscopic evaluation, and final haematoxylin and eosin analysis, were analysed. RESULTS: All specimen preparations and CFM scanning were completed within 5 min. Interobserver agreement between the two pathology reviewers was 91.7%. When compared with final histopathology, expert pathology readers achieved strong diagnostic performance using CFM, with a sensitivity of 87.5%, specificity of 90%, positive predictive value (PPV) of 87.5%, and negative PV(NPV) of 90%. By comparison, the urology trainees yielded a sensitivity of 61.9%, specificity of 100%, PPV of 100%, and NPV of 66.7%, while standard cystoscopic assessment demonstrated a sensitivity, specificity, PPV, and NPV of 100%, 50%, 71.4%, and 100%, respectively. CONCLUSION: Confocal fluorescence microscopy represents a feasible and promising adjunct for real-time intraoperative assessment of TURBT specimen adequacy and resection quality. Although expert pathology readers demonstrated superior diagnostic performance, acceptable accuracy can also be achieved by urology trainees with necessary training and additional experience. Nevertheless, larger, multi-institutional studies remain required to validate these findings and to further define the safe implementation of CFM in contemporary diagnosis and surgical management of bladder cancer.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Soputro NA, Wang L, Daher K, et al. Intraoperative evaluation of detrusor muscle during transurethral resection of bladder tumour using confocal fluorescent microscopy. BJU Int. 2026. PMID: 41672610. doi:10.1111/bju.70165

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。