文献速递前列腺癌

共聚焦显微镜在机器人辅助前列腺切除术中的可行性与工作流程分析

Feasibility and workflow analysis of confocal microscopy in robot-assisted prostatectomy.
PubMed 文献 · BJU Int · 2026-02-08

该研究纳入66例非转移性前列腺癌患者,在神经保留机器人辅助根治性前列腺切除术中同时使用荧光共聚焦显微镜(HS)和冰冻切片(FS)进行术中切缘评估。以全切片组织学为参考标准,HS在明确诊断时灵敏度60.0%、特异度98.1%、阳性预测值75.0%、阴性预测值96.4%,且不影响下游免疫组化及二代测序分析。

要点

  • HS阴性结果可信度高,阴性预测值96.4%,或可减少冰冻切片需求。
  • HS阳性或可疑结果应行靶向冰冻切片确认。
  • HS处理后的残余组织不影响免疫组化及二代测序分析。

核心结论

  • 荧光共聚焦显微镜在机器人辅助根治性前列腺切除术的术中切缘评估中具有高特异度和阴性预测值。

研究设计与样本

  • 前瞻性纳入2024年5月至2025年4月间68例接受机器人辅助根治性前列腺切除术的非转移性前列腺癌患者,排除2例数据不完整,最终66例可评估。
  • 术中同时使用荧光共聚焦显微镜(Histolog® Scanner)和冰冻切片进行切缘评估,HS图像由经验丰富的泌尿病理学家术中判读,手术决策基于冰冻切片结果。
  • 以全切片组织学为参考标准评估诊断性能,并评估HS处理后残余组织对下游免疫组化和二代测序的兼容性。

主要发现

  • HS在4例中识别出癌(3例真阳性、1例假阳性),55例阴性切缘(53例真阴性、2例假阴性),7例(10.6%)分类为可疑并由冰冻切片解决。
  • 仅考虑明确HS诊断时,灵敏度60.0%、特异度98.1%、阳性预测值75.0%、阴性预测值96.4%。
  • 将可疑病例视为阳性时,灵敏度升至75.0%、特异度降至91.4%、阳性预测值降至54.5%,阴性预测值保持96.4%。
  • HS处理未损害免疫组化或二代测序分析。
  • 总体R1切除率为9.1%。

临床怎么用

  • HS阴性结果可高置信度解读,可能减少对冰冻切片的需求。
  • HS阳性或可疑发现应促使靶向冰冻切片确认。
  • 共聚焦激光扫描显微镜保留组织完整性以供分子检测,可整合入多模式肿瘤学工作流程。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To assess the diagnostic accuracy, workflow feasibility, and downstream compatibility of fluorescence confocal microscopy (Histolog® Scanner [HS]; SamanTree Medical SA, Lausanne, Switzerland) compared with frozen section (FS) for intraoperative margin evaluation (IME) during nerve-sparing robot-assisted radical prostatectomy (RARP). PATIENTS AND METHODS: Between May 2024 and April 2025, 68 patients undergoing RARP for non-metastatic prostate cancer were enrolled; two were excluded due to incomplete data, leaving 66 evaluable cases. The IME was performed using both HS and FS. HS images were interpreted intraoperatively by experienced uropathologists, while surgical decisions were based on FS results. The residual tissue following HS was assessed for compatibility with downstream immunohistochemistry (IHC) and next-generation sequencing (NGS). Diagnostic performance was evaluated against whole-mount histology as the reference standard. RESULTS: The HS identified carcinoma in four cases (three true positives, one false positive) and negative margins in 55 cases (53 true negatives, two false negatives); seven cases (10.6%) were classified as suspicious and resolved by FS. Considering only definite HS calls, sensitivity was 60.0%, specificity 98.1%, positive predictive value (PPV) 75.0%, and negative predictive value (NPV) 96.4%. When suspicious cases were treated as positive, sensitivity increased to 75.0%, specificity decreased to 91.4%, and PPV to 54.5%, while NPV remained 96.4%. HS processing did not impair IHC or NGS analyses. The overall R1 resection rate was 9.1%. CONCLUSION: Fluorescence confocal microscopy demonstrates high specificity and NPV for IME during RARP. A negative HS result can be interpreted with high confidence, potentially reducing the need for FS. Positive or suspicious HS findings should prompt targeted FS confirmation. Confocal laser scanning microscopy preserves tissue integrity for molecular testing and may be integrated into multimodal oncological workflows.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Skok K, Scheipner L, Mannweiler S, et al. Feasibility and workflow analysis of confocal microscopy in robot-assisted prostatectomy. BJU Int. 2026. PMID: 41655999. doi:10.1111/bju.70157

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。