文献速递前列腺增生与排尿功能障碍

居家音频尿流率与诊室尿流率的相关性评估:迈向新金标准

Assessing the Correlation of At-home Audio Testing and In-office Uroflowmetry: Moving Towards a New Gold-standard.
PubMed 文献 · Urology · 2025-12-18

诊室Qmax可能无法准确反映患者自然排尿模式,居家测试具有潜在价值。

要点

  • 未校正排尿量时,诊室与居家平均最大尿流率不相关。
  • 校正排尿量后,两者显著相关,提示排尿量是重要混杂因素。
  • 居家平均排尿量是诊室的2.18倍(SD 1.67),诊室单次排尿可能偏低。

核心结论

  • 校正排尿量后诊室与居家平均最大尿流率显著相关,居家音频尿流率有潜力补充诊室评估。

主要发现

  • 患者居家平均排尿量是诊室排尿量的2.18倍(SD 1.67)。

临床怎么用

  • 解读诊室尿流率时应考虑排尿量影响,单次诊室Qmax可能低估患者自然排尿功能。
  • 居家多次音频尿流率或可提供更接近自然状态的排尿参数,但需进一步验证。

局限性

  • 未报告音频尿流率的具体准确性指标及临床可接受阈值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To determine whether audio-based uroflowmetry is equivalent in accuracy and reliability to the in-clinic gold standard. METHODS: Men over age 18 with a chief complaint of lower urinary tract symptoms (LUTS) conducted a standard in-office uroflowmetry and used the Emano Flow phone application for 1 week to conduct audio-based uroflowmetry. Pearson correlation coefficient (PCC) was utilized to assess the relationship between conventional and the mean of audio-based Qmax after adjusting for the effect of void volume by performing residualization. RESULTS: Thirty-two participants were recruited. On average, a patient's home volume was 2.18x (SD 1.67) higher than their clinic volume. Prior to adjusting for void volume, conventional and the mean of multiple at-home maximum flow rates were not correlated (PCC = 0.21, P = .31). After adjusting for void volume, conventional and mean of multiple at-home Qmax were significantly correlated (PCC = 0.41, P = .04). CONCLUSION: Prior to adjusting for void volume, conventional and at-home maximum flow rates were not correlated. This can be explained, in part, by patients having one uncharacteristically low in-clinic on-demand void. Once we adjusted for void volume, office and at-home Qmax were correlated. As office Qmax may not accurately capture a patient's natural voiding patterns, our findings underscore the potential value of at-home testing. Further work is needed to improve the tools that we use for diagnosing and evaluating LUTS.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Grant RS, Scotland KB, Thaker KN, et al. Assessing the Correlation of At-home Audio Testing and In-office Uroflowmetry: Moving Towards a New Gold-standard. Urology. 2025. PMID: 41421555. doi:10.1016/j.urology.2025.12.016