前列腺癌活检全切片远程病理分级:ISUP标准下观察者间与观察者内一致性及主动监测启示
本研究首次基于当代国际泌尿病理学会(ISUP)标准,利用全切片图像对前列腺癌穿刺活检进行远程病理分级一致性研究。观察者间加权Kappa为0.34(95%CI 0.28,0.39),观察者内为0.49(95%CI 0.46,0.53),GG1与GG2区分一致性较差,对主动监测决策有重要影响。
要点
- 前列腺癌活检GG分级观察者间一致性仅为fair(κw=0.34)。
- GG1与GG2区分困难,尤其当pattern 4占比1%–10%时。
核心结论
- 前列腺癌活检GG分级观察者间和观察者内变异性显著,尤其区分GG1与GG2(≤10% grade 4)时。
- 这些观察对治疗决策(监测 vs 根治性治疗)及新型生物标志物和影像学研究有深远影响。
研究设计与样本
- 研究纳入120例前列腺癌活检病例的全切片图像,涵盖不同GG。
- 共识定义为≥7名病理学家对GG一致。
主要发现
- 86/120(72%)病例达到共识。
- 未达共识的34例中,多数为GG2 vs GG1(41%)或GG2 vs GG3(38%)。
- 观察者间加权Kappa为0.34(95%CI 0.28,0.39),一致性fair。
- 重复评分不一致中38%涉及GG1 vs GG2;其中77%报告1%至10% pattern 4,常见观察为「poorly formed glands」。
关键数值与推荐
- 共识标准:≥7名病理学家对GG一致。
- 观察者间加权Kappa 0.34(95%CI 0.28,0.39)。
- 观察者内加权Kappa 0.49(95%CI 0.46,0.53)。
临床怎么用
- 临床决策(如主动监测 vs 根治性治疗)需考虑GG分级观察者间变异性。
- 对GG1与GG2区分(尤其pattern 4 1%–10%)应谨慎,必要时寻求专家会诊。
- 基于GG分级的研究(生物标志物、影像)需考虑分级一致性影响。
局限性
- 未报告病理学家经验水平对一致性的影响。
- 远程病理评估环境可能不同于常规临床实践。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Subjectivity of prostate cancer (PCa) grading affects biomarker investigations, assessments of imaging, and treatment decisions, especially for active surveillance. We conducted the first telepathology concordance study of PCa needle biopsy grading using contemporary International Society of Urologic Pathology guidelines. METHODS: Whole slide images (n = 120) of PCa biopsy cases across grade groups (GGs) were examined by 11 urologic pathologists. Forty cases were blindly regraded, oversampling cases with lower agreement on first review. Pathologists provided GG, percentage and type of pattern Gleason 4, and tumor length. Consensus for a case was defined as GG agreement by ≥ 7 pathologists. GG agreement among and within pathologists was measured using model-based weighted Kappa statistics (κw). RESULTS: Consensus was achieved on 86/120 (72%) cases. Of 34 cases not achieving consensus, most were GG2 vs GG1 (41%) or GG2 vs GG3 (38%). The inter-rater κw was 0.34 (95% CI 0.28, 0.39) indicating fair agreement. Forty regraded cases had an intra-rater κw of 0.49 (95% CI 0.46, 0.53; moderate agreement). Sixty-four percent of the repeated grades agreed. Of the repeated ratings that did not agree, 38% involved GG1 vs GG2. Of the GG1 vs GG2 paired repeated ratings, 77% reported 1% to 10% pattern 4, and indicated common observation was "poorly formed glands." DISCUSSION: Inter-rater and intra-rater variability in GG is significant, particularly discerning GG1 from GG2 with ≤ 10% grade 4. These observations have profound implications for treatment decisions (surveillance vs definitive therapy) and studies of new biomarkers and imaging of prostate cancer.
引用
- Lucia MS, Callis S, Tangen C, et al. Whole-Slide Telepathology Grading of Prostate Cancer in Biopsies Using International Society of Urological Pathology Criteria: Interobserver and Intraobserver Concordance and Implications for Active Surveillance. J Urol. 2025. PMID: 41461080. doi:10.1097/JU.0000000000004919
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。