单中心随机试验纳入150例8-25 mm肾结石患者,比较高功率(16-18 W)与低功率(4-6 W)铥光纤激光输尿管镜碎石术。高功率未缩短手术时间,低功率在无残留结石率(Grade A 63% vs 44%)和≤2 mm残留率(Grade B 77% vs 56%)上更优,且术后轻微并发症更少(11% vs 37%)。
要点
- 高功率未缩短手术时间,中位时间48 vs 54分钟(P=0.12)。
- 低功率 Grade A 无结石率63% vs 高功率44%(P=0.02)。
- 低功率轻微术后并发症11% vs 高功率37%(P<0.001)。
核心结论
- 高功率未缩短手术时间,低功率改善无结石率并减少轻微并发症,支持低功率作为无鞘输尿管镜碎石默认策略。
研究设计与样本
- 单中心随机对照试验(1:1),挪威Haukeland大学医院,纳入150例接受日间输尿管镜碎石的8-25 mm肾结石成人患者。
主要发现
- 手术时间中位数高功率48分钟 vs 低功率54分钟(P=0.12)。
- 高功率能量使用更多(12 vs 7 kJ,P<0.001),激光激活时间更短(13 vs 24分钟,P<0.001)。
- Grade A 无结石率低功率63% vs 高功率44%(P=0.02);Grade B 低功率77% vs 高功率56%(P=0.008)。
- 低功率镜下视野更佳,轻微术后并发症更少(11% vs 37%,P<0.001)。
- 主要并发症(Clavien-Dindo ≥III级)少见且两组相似。
关键数值与推荐
- 高功率设定16-18 W,低功率设定4-6 W,均未使用输尿管通道鞘。
- 结石无残留分级:Grade A无残留,Grade B≤2 mm,Grade C≤4 mm,Grade D>4 mm。
- 3个月非增强CT评估无结石率,并发症按Clavien-Dindo分级。
临床怎么用
- 无鞘输尿管镜碎石可优先选择低功率铥光纤激光策略以改善无结石率并减少轻微并发症。
局限性
- 单中心研究,结果反映该中心常规实践(均未使用输尿管通道鞘),外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare operative time and clinical outcomes between high-power (HP) and low-power (LP) thulium fibre laser (TFL) ureteroscopic (URS) lithotripsy for renal stones. PATIENTS AND METHODS: Single-centre, randomised trial (1:1) at Haukeland University Hospital, Norway. Adults undergoing day-case URS for 8-25 mm renal stones were enrolled. A total of 150 cases were included. Patients were randomised to URS lithotripsy with TFL using HP (16-18 W, selected for thermal safety during sheathless URS) or LP (4-6 W). The primary endpoint was operative time. The secondary endpoints were stone-free rate (SFR) on 3-month non-contrast computed tomography (Grade A: no residuals; Grade B: ≤2 mm; Grade C: ≤4 mm; Grade D: >4 mm), laser metrics, performance measures, and complications according to the Clavien-Dindo Classification. Groups were compared using appropriate parametric and non-parametric tests (two-sided α = 0.05). RESULTS: A ureteric access sheath was not used in any case, reflecting routine practice at our centre. The operative time did not differ between arms: median (interquartile range) HP 48 (36-62) vs LP 54 (42-65) min (P = 0.12). HP used more energy (12 vs 7 kJ, P < 0.001) with shorter active laser time (13 vs 24 min, P < 0.001), but laser operating time was similar. SFRs favoured LP compared to HP: Grade A, 63% vs 44% (P = 0.02); Grade B, 77% vs 56% (P = 0.008). The Grade C SFR was similar between arms. LP was also associated with better surgeon-rated endoscopic visibility and fewer minor postoperative complications (11% vs 37%, P < 0.001). Major complications (Clavien-Dindo Grade ≥III) were uncommon and similar between arms. CONCLUSION: Using HP did not shorten the operative time. LP improved SFRs for Grade A/B and reduced minor postoperative morbidity, supporting LP as the default TFL strategy for sheathless URS lithotripsy.
引用
- Æsøy MS, Juliebø-Jones P, Gjengstø P, et al. Watt's the difference? A randomised trial of high- vs low-power ureteroscopic thulium fibre laser lithotripsy. BJU Int. 2025. PMID: 41429432. doi:10.1111/bju.70123