文献速递泌尿系结石

计算机视觉模型自动分割肾结石及其与外科医生性能比较

A computer vision model for automated kidney stone segmentation and evaluation of its performance vs surgeons.
PubMed 文献 · BJU Int · 2025-09-25

模型整体Dice相似系数为0.97,分割速度达30帧/秒,性能与五位专家外科医生相当,并在头对头比较中显著优于其中三位。

要点

  • 模型在结石分割上Dice相似系数达0.97,且可30帧/秒实时运行。
  • 模型性能与五位认证泌尿外科医生整体相当,且显著优于其中三位。
  • 模型在残石评估时性能略低(Dice 0.91),但仍在可接受范围。

核心结论

  • 计算机视觉模型在URS中结石分割表现良好,性能与专家外科医生相似,具备实时术中应用的可行性。

研究设计与样本

  • 收集136个肾内结石URS治疗视频,按3帧/秒提取帧并手动标注,数据集分为训练集(75%)、验证集(5%)和测试集(20%)。
  • 模型性能通过受试者工作特征曲线下面积、二元交叉熵损失和Dice相似系数评估,并与五位委员会认证泌尿外科医生的手动标注进行逐帧分割准确性配对比较。

主要发现

  • 模型整体Dice相似系数为0.97(四分位距[IQR] 0.91, 0.99),分割速度达30帧/秒。
  • 纤维镜和数字镜性能相似:纤维镜Dice 0.97(IQR 0.91, 0.99),数字镜Dice 0.97(IQR 0.92, 0.99)。
  • 模型在结石定位时Dice为0.98(IQR 0.93, 0.99),激光消融时为0.96(IQR 0.89, 0.97),残石评估时略低为0.91(IQR 0.50, 0.97)。
  • 模型整体性能与五位专家外科医生相当;头对头比较中,模型显著优于三位专家,与另外两位表现相似。

临床怎么用

  • 该模型有望在URS术中实时辅助结石分割,提升可视化效果,辅助外科医生决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To develop a computer vision model that segments stones to improve visualisation during ureteroscopy (URS) and to compare model performance to that of experts. MATERIALS AND METHODS: We collected 136 videos of URS for intrarenal kidney stone treatment. Frames were extracted at 3 frames per second (FPS) and manually annotated. The video dataset was split into training (75%), validation (5%) and testing (20%) subsets. Model performance was evaluated for stone localisation, laser ablation, and final evaluation of remaining fragments based on area under the receiver-operating curve, binary cross-entropy loss and Dice similarity coefficient (DSC). Model performance was compared to the manual annotations of five board-certified urologists through pairwise comparison of frame-by-frame segmentation accuracy. RESULTS: The final dataset consisted of 21 718 frames from 38 fibreoptic and 98 digital videos. Overall, the model showed excellent performance: DSC 0.97 (interquartile range [IQR] 0.91, 0.99) and could segment at 30 FPS. Performance was similar for both fibreoptic (0.97 [IQR 0.91, 0.99]) and digital scopes (0.97 [IQR 0.92, 0.99]). Additionally, the model demonstrated good performance during stone localisation (0.98 [IQR 0.93, 0.99]) and stone laser ablation (0.96 [IQR 0.89, 0.97]), with slightly worse performance during evaluation of residual fragments (0.91 [IQR 0.50, 0.97]). Model performance was comparable to the five expert surgeons overall. In a head-to-head comparison, the model significantly outperformed three of the five experts and performed similarly to the other two. CONCLUSION: The computer vision model demonstrates good performance for task-specific stone segmentation evaluation during URS. The segmentation performance of the model was similar to the segmentation performance of expert surgeons, demonstrating the feasibility of its real-time intra-operative utilisation.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Lu D, Deol ES, Koyama T, et al. A computer vision model for automated kidney stone segmentation and evaluation of its performance vs surgeons. BJU Int. 2025. PMID: 40994261. doi:10.1111/bju.70001