女性跑者盆底负荷与跑步后盆底形态或功能变化的关系
研究纳入有或无跑步诱发压力性尿失禁的女性跑者各19例,完成37分钟跑步方案并测量盆底负荷。跑步后提肛肌裂孔增大、膀胱颈位置下移,但盆底肌力无显著变化;盆底负荷大小与这些静态支撑变化及漏尿量无关。
要点
- 跑步后出现提肛肌裂孔增大和膀胱颈下移,但盆底肌主动或被动力量无显著变化。
- 有和无跑步诱发压力性尿失禁者上述变化无差异。
- 骨盆加速度较高与跑后被动盆底肌刚度下降更多相关,但与形态变化无关。
核心结论
- 跑步时盆底负荷的大小似乎不影响跑步后观察到的静态盆腔器官支撑的短暂丧失,也不影响漏尿量。
研究设计与样本
- 研究纳入有(n=19)和无(n=19)跑步诱发压力性尿失禁的成年女性跑者,完成37分钟跑台跑步方案,并在跑前跑后评估盆底形态和盆底肌功能。
主要发现
- 跑步后提肛肌裂孔增大且膀胱颈在盆腔内位置更低,但用动力计测量的盆底肌主动或被动力量无显著差异。
- 这些变化在有和无跑步诱发压力性尿失禁的跑者之间无差异。
- 较高的骨盆加速度与跑后被动盆底肌刚度下降更多相关(R2=20%-27%),但与盆底形态变化无关。
- 任何盆底负荷暴露指标与盆底肌力产生能力变化之间均无关联。
- 在有跑步诱发压力性尿失禁的跑者中,向量加速度较慢者跑后尿垫增重更多(R2=0.27)。
临床怎么用
- 女性跑者跑步后出现的静态盆腔器官支撑下降和漏尿量可能不单纯由盆底负荷大小决定,临床评估需综合考虑其他因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To investigate whether, among female runners, transient changes in pelvic floor morphometry, pelvic floor muscle (PFM) function, or pad weight gain observed after a standardised running protocol are associated with the exposure of the pelvic floor to loading during the run. METHODS: Adult female runners with (n = 19) and without (n = 19) running-induced stress urinary incontinence (RI-SUI) completed a 37-min treadmill-based running protocol with a pressure sensor placed in the posterior fornix of the vagina and a triaxial accelerometer adhered to the pelvis, and an incontinence pad adhered to their undergarment. Pelvic morphometry and PFM function were assessed before and after the run using transperineal ultrasonography and intra-vaginal dynamometry. Urine leakage volume was estimated based on incontinence pad weight gain. Separate linear regression models were used to evaluate the associations between variables representative of pelvic floor load exposure (posterior fornix sensor pressure [PFSP] and pelvic accelerations) and changes in pelvic morphometry, PFM function, and incontinence pad weight observed after the run. RESULTS: After the run, the levator hiatus was larger and the bladder neck sat lower in the pelvis, but there were no significant differences in PFM active or passive forces measured using dynamometry. These changes were not different between those with and those without RI-SUI. Higher pelvic accelerations were associated with greater reductions in passive PFM stiffness after the run (R2 = 20%-27%), but not with changes in pelvic morphometry. No associations were found between any measures of pelvic floor load exposure and changes in PFM force-generating capacity. Among runners with RI-SUI, greater pad weight gain occurred among those who ran with slower vector accelerations (R2 = 0.27). CONCLUSION: The magnitude of pelvic floor loading experienced during running does not appear to influence the transient loss in static pelvic organ support observed after running nor urine leakage volume.
引用
- Berube ME, Niederauer S, Graham R, et al. Is pelvic floor loading in female runners associated with post-run changes in pelvic floor morphometry or function? BJU Int. 2025. PMID: 40586130. doi:10.1111/bju.16842
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。