可弯曲可导航吸引输尿管鞘:能清除多大结石颗粒?
本研究通过台式实验评估可弯曲可导航吸引(FANS)输尿管鞘(UAS)配合不同尺寸输尿管镜清除不同大小结石颗粒的能力。使用石英石模拟结石,在30°角度下每3分钟加入等分试样模拟激光碎石过程,采用11/13-F ClearPetra® FANS UAS和200-mmHg吸引。结果显示,持续留置9.5-F输尿管镜时清除64%总结石质量但平均21分钟堵塞;间歇退出输尿管镜可完全清除;留置7.5-F和6.3-F输尿管镜时未堵塞,分别完全清除≤500 μm和≤2 mm的结石。
要点
- 持续留置9.5-F输尿管镜时FANS UAS平均21分钟堵塞,清除64%结石质量。
- 间歇退出输尿管镜可实现完全结石清除。
- 留置7.5-F和6.3-F输尿管镜时未堵塞,分别完全清除≤500 μm和≤2 mm结石。
核心结论
- 不退出输尿管镜时,7.5-F和6.3-F输尿管镜配合11/13-F FANS UAS可连续吸引小碎片。
- 间歇退出输尿管镜可实现完全结石清除。
研究设计与样本
- 台式实验,使用石英石模拟1-cm草酸钙结石激光粉末化产生的颗粒范围,每3分钟加入等分试样共30分钟,11/13-F ClearPetra® FANS UAS,三种输尿管镜尺寸(9.5-F Lithovue™、7.5-F PUSEN、6.3-F Hugemed),每种输尿管镜实验重复四次。
主要发现
- 持续留置9.5-F输尿管镜时,FANS UAS清除64%总结石质量,平均21分钟堵塞。
- 间歇退出9.5-F输尿管镜时清除所有结石。
- 留置7.5-F输尿管镜时未堵塞,完全清除≤500 μm结石。
- 留置6.3-F输尿管镜时未堵塞,完全清除≤2 mm结石。
关键数值与推荐
- 使用11/13-F ClearPetra® FANS UAS,间歇填充至40 mL水,200-mmHg吸引。
- 结石混合物在30°角度下每3分钟加入等分试样共30分钟。
临床怎么用
- 临床使用FANS UAS时,若需连续激光碎石,可选择7.5-F或6.3-F输尿管镜以维持吸引并避免堵塞。
- 为清除较大碎片,可间歇退出输尿管镜以通过空鞘管腔清除结石。
局限性
- 台式模型仅关注FANS鞘与输尿管镜之间的几何形状和吸引效应,排除了复杂流体动力学。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To perform benchtop experiments on flexible and navigable suction (FANS) ureteric access sheaths (UASs) to determine the clearance capabilities for various stone sizes when paired with different-sized ureteroscopes. METHODS: Quartz stones were used as a surrogate for renal stones. Stone samples were created to simulate the range of particle sizes produced by 'dusting' a 1-cm calcium oxalate monohydrate stone. The stone mixture was introduced into an open vial at a 30° angle in aliquots every 3 min over the course of 30 min, mimicking their gradual production by lasertripsy. This benchtop model focused on the effects of geometry (between FANS access sheath and ureteroscope) and suction, excluding complex fluid flow. An 11/13-F ClearPetra® FANS UAS with an indwelling ureteroscope was free to move in the vial and targeted visible stones. The vial was intermittently filled to 40 mL with water and emptied using 200-mmHg suction. The experiment had two arms: (1) a permanently indwelling ureteroscope in the FANS UAS to mimic continuous lasering with aspiration and (2) intermittent withdrawal of the ureteroscope to mimic pausing lasering to clear larger fragments through the empty FANS sheath lumen. Three ureteroscope sizes were used: 9.5-F (Lithovue™), 7.5 F (PUSEN) and 6.3 F (Hugemed). The experiment was performed four times for each ureteroscope. [Correction added on 4 July 2025, after first online publication: In the preceding sentence, "three" has been corrected to "four" in this version.] RESULTS: With a permanently indwelling 9.5-F ureteroscope, the FANS UAS cleared 64% of the overall stone mass but became blocked after an average of 21 min. Intermittent withdrawal of the ureteroscope cleared all stones. With indwelling 7.5-F and 6.3-F ureteroscopes, the FANS UAS did not become blocked and completely cleared stones of up to 500 μm and 2 mm, respectively. CONCLUSIONS: Without withdrawing the ureteroscope (potentially allowing continuous lasertripsy), it is possible to continuously aspirate small fragments alongside a 7.5-F and a 6.3-F ureteroscope in an 11/13-F FANS UAS. Intermittent withdrawal of a ureteroscope from the FANS UAS allows complete stone clearance.
引用
- Menzies-Wilson R, Williams J, Ayyappan K, et al. Flexible and navigable suction access sheaths: what size stone particles can be cleared? BJU Int. 2025. PMID: 40583112. doi:10.1111/bju.16844
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。