声学增强微泡空化:评估泌尿系结石新型治疗方法安全性与有效性的随机临床试验
本研究将泌尿系结石患者随机分为输尿管镜激光碎石联合或不联合声学增强微泡空化两组,主要终点为术后30天CT无≥2 mm残留碎片比例及不良事件。研究组与对照组无残留碎片率分别为41%和47%(P=.46),不良事件发生率分别为35%和46%(P=.11),研究组不良事件总数更少(P<.001)。
要点
- 研究组与对照组无残留碎片率分别为41%和47%(P=.46),两组无统计学优效性。
- 研究组和对照组不良事件发生率分别为35%和46%(P=.11),研究组不良事件总数更少(P<.001)。
- 研究组中平均功率≥12 W者无残留碎片率为51%,低功率组为32%(n=47)(P=.06)。
核心结论
- 联合微泡空化的激光碎石未提高疗效,但与显著更少的不良事件相关。
- 微泡空化的疗效可能取决于所用激光功率。
- 输尿管镜的低疗效和高不良事件率凸显了泌尿系结石新型管理方法的必要性。
研究设计与样本
- 随机临床试验,纳入泌尿系结石患者,随机分为输尿管镜激光碎石联合或不联合声学增强微泡空化两组。
- 研究组103例,对照组93例。
- 主要终点为术后30天CT无≥2 mm残留碎片比例(无碎片率)和不良事件。
主要发现
- 研究组与对照组无残留碎片率分别为41%和47%(P=.46),两组间无统计学优效性。
- 研究组与对照组残留碎片大小分别为5.55 mm和5.70 mm(P=.71)。
- 研究组中平均功率≥12 W者无残留碎片率为51%,低功率组为32%(n=47)(P=.06)。
- 研究组与对照组不良事件发生率分别为35%和46%(P=.11)。
- 研究组不良事件总数少于对照组(P<.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The efficacy of ureteroscopy to treat urinary stones is often less than 60%. Acoustic Enhancer is an investigational device of microparticles with a tag designed with an affinity for calcium. We evaluated safety and efficacy of ureteroscopic laser lithotripsy with and without Acoustic Enhancer Microbubble Cavitation in a randomized clinical trial. MATERIALS AND METHODS: Patients with urolithiasis were randomized to ureteroscopic laser lithotripsy with or without Acoustic Enhancer. The end points were the proportion of patients without residual fragments ≥ 2 mm on CT 30 days post procedure (fragment-free rate) and adverse events (AEs). RESULTS: There were 103 and 93 patients in the investigational and control groups, respectively. There was no statistical superiority between the 2 groups. The fragment-free rate was 41% and 47% in the investigational and control groups, respectively (P = .46). Residual fragment size was similar, 5.55 mm vs 5.70 mm for the investigational and control groups, respectively (P = .71). Among investigational patients treated with higher average powers ≥ 12 W, the fragment-free rate was 51% compared with 32% (n = 47) for the low-power group (P = .06). AEs were noted in 35% and 46% of patients in the investigational and control groups, respectively (P = .11). The total number of AEs was less for the investigational arm (P < .001). CONCLUSIONS: Although laser lithotripsy with microbubble cavitation did not increase efficacy, it was associated with significantly fewer AEs. Efficacy of microbubble cavitation may depend on laser power used. The low efficacy and high rates of AEs with ureteroscopy highlight the need for novel management approaches for urinary stones.
引用
- Mayer WA, Chi T, Wiener S, et al. Acoustic Enhancer Microbubble Cavitation: A Randomized Clinical Trial Evaluating the Safety and Efficacy of a Novel Treatment for Urolithiasis. J Urol. 2025. PMID: 40286438. doi:10.1097/JU.0000000000004581
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。