文献速递男科与性医学

手动灵活性预测充气式阴茎假体成功度的研究

Manual Dexterity Predictors of Inflatable Penile Prosthesis Success.
PubMed 文献 · Urology · 2025-02-07

本研究探讨术前灵活性评估能否预测勃起功能障碍患者充气式阴茎假体(IPP)置入术后成功率。29例患者术前接受9孔钉柱计时测试、捏力与握力评估及上肢功能障碍问卷,术后3个月问卷调查满意度、使用难度、信心及勃起改善。结果显示握力与使用难度呈负相关(P=0.037),年龄增加与使用信心降低相关(P=0.068),钉柱测试、捏力及握手强度无统计学意义。

要点

  • 握力与IPP使用难度呈负相关(P=0.037)。
  • 年龄增加与使用信心降低相关(P=0.068)。
  • 钉柱测试、捏力及握手强度无统计学意义。

核心结论

  • 握力是术前IPP评估中有用的辅助手段,适用于手动功能状态不明确的患者。
  • 这些测试便宜且易于在诊所进行。

研究设计与样本

  • 术前对29例接受IPP置入的勃起功能障碍患者进行9孔钉柱计时测试、捏力与握力评估及上肢功能障碍问卷(DASH)。
  • 术后3-4周进行初始装置循环和泵位置评估,术后3个月进行满意度、使用难度、信心及勃起变化问卷调查。
  • 分析术前评估变量与术后问卷之间的相关性。

主要发现

  • 术后65.5%的患者满意,41.4%报告无使用困难,75.8%在1个月时对装置使用有信心,68.9%评价勃起为大幅改善或极大改善。
  • 握力与使用难度呈负相关(P=0.037)。
  • 年龄增加与装置使用信心降低相关(P=0.068)。
  • 钉柱测试、捏力及握手强度无统计学意义。

临床怎么用

  • 作者认为握力是术前IPP评估中有用的辅助手段,用于手动功能状态不明确的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate the ability of preoperative dexterity assessments to predict postoperative success of inflatable penile prosthesis (IPP) placement for erectile dysfunction. MATERIALS: A timed 9-hole peg test, pinch and grip strength assessment, and Disabilities of the Arm Shoulder and Hand questionnaire were administered during the preoperative visit before IPP placement. In addition to standard preoperative workup, subjective handshake strength was recorded. Initial device-cycling and assessment of pump placement occurred 3-4 weeks after surgery. Three months postoperatively, a survey measuring satisfaction, difficulty of use, confidence, and erectile change was administered. Correlation between preoperative assessment variables and the postoperative questionnaire was assessed. RESULTS: Twenty-nine patients were included. Mean age and BMI were 63.0 years and 30.7 kg/m2, respectively. Postoperatively, 65.5% of patients were satisfied; 41.4% reported no difficulty of use; and 75.8% were confident in device use by 1 month. 68.9% rated their erection as much improved or very much improved. Grip strength was inversely associated with difficulty of use (P = 0.037). There was an association between increased age and decreased confidence of device use (P = 0.068). Peg test, pinch strength, and handshake were not statistically significant. CONCLUSION: Grip strength is a useful adjunct to assess manual functional status during preoperative IPP evaluation for patients whose manual functional status is unclear. These tests are inexpensive and easy to perform in the clinic.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Campbell K, Singh SM, Vetter J, et al. Manual Dexterity Predictors of Inflatable Penile Prosthesis Success. Urology. 2025. PMID: 39924118. doi:10.1016/j.urology.2025.01.074

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。