活体猪模型中肾盂压力与输尿管镜术后感染的关系
在活体猪模型中,比较肾盂压力37 mmHg与75 mmHg下输尿管镜灌注盐水或含大肠杆菌菌株CFT073盐水对感染的影响。75 mmHg加菌组炎症标志物显著高于对照组和37 mmHg加菌组,该组7只动物中5只血培养阳性,其他组无菌血症。
要点
- 75 mmHg加菌组炎症标志物较对照组和37 mmHg加菌组显著升高
- 75 mmHg加菌组7只动物中5只血培养阳性,其他组未出现菌血症
- 在猪模型中,较高肾盂压力下灌注含菌盐水与菌血症和炎症反应相关
核心结论
- 在猪输尿管镜模型中,75 mmHg肾盂压力下灌注含大肠杆菌菌株CFT073的盐水导致菌血症和炎症标志物升高,显著高于37 mmHg加菌组和对照组。
研究设计与样本
- 活体猪模型研究,麻醉猪行1小时输尿管镜,使用压力感知导丝维持肾盂压力37 mmHg或75 mmHg,灌注盐水或标准化浓度大肠杆菌菌株CFT073(1.5 × 10^7 CFU/mL),共21只猪肾。
主要发现
- 研究分组:37 mmHg盐水灌注组(n=3);75 mmHg盐水灌注组(n=4);37 mmHg盐水加1.5 × 10^7 CFU/mL大肠杆菌组(n=7);75 mmHg盐水加1.5 × 10^7 CFU/mL大肠杆菌组(n=7)。
- 炎症标志物的统计学显著变化在75 mmHg盐水加大肠杆菌组最为明显,且显著高于对照组和37 mmHg大肠杆菌灌注组。
- 75 mmHg加菌组7只动物中5只血培养阳性;其他组未出现菌血症。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the relationship between renal pelvis pressure and infection after ureteroscopy, using a live swine model. MATERIALS AND METHODS: In anaesthetised pigs, a 1-h ureteroscopy was performed using a pressure-sensing guidewire, with renal pelvis pressure maintained at either 37 mmHg or 75 mmHg for the entire procedure and infusion with saline alone or with a standardised concentration of uropathogenic Escherichia coli strain CFT073 (1.5 × 107 colony-forming units [CFU]/mL). Venous blood sampling was performed during and after the procedure. Vital signs, inflammatory biomarkers, and renal tissue and blood cultures were assessed. RESULTS: In 21 pig kidneys, study groups were: 37 mmHg with saline irrigation (n = 3); 75 mmHg with saline irrigation (n = 4); 37 mmHg with saline irrigation with 1.5 × 107 CFU/mL E. coli (n = 7); and 75 mmHg with saline irrigation with 1.5 × 107 CFU/mL E. coli (n = 7). Statistically significant changes in inflammatory biomarkers were most pronounced in the group with 75 mmHg saline irrigation + E. coli and were significantly elevated compared with the control group and the group receiving E. coli irrigation at 37 mmHg. Positive blood cultures were noted in 5/7 animals treated with E. coli at 75 mmHg; no others developed bacteraemia. CONCLUSION: In this swine model of ureteroscopy, irrigation with saline + E. coli at a renal pelvis pressure of 75 mmHg resulted in bacteraemia and inflammatory biomarker elevations significantly greater than both E. coli irrigation with renal pelvis pressure maintained at 37 mmHg and the control.
引用
- Hinojosa-Gonzalez D, Kottooran C, Saunders J, et al. Relationship between renal pelvis pressure and post-ureteroscopy infection in a live swine model. BJU Int. 2024. PMID: 39448382. doi:10.1111/bju.16539
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。