文献速递泌尿系结石

输尿管镜碎石术中特伦德伦伯卧位或反特伦德伦伯卧位体位的影响:系统综述与荟萃分析

Impact of Either Trendelenburg or Reverse Trendelenburg Positioning for Ureteroscopy Lithotripsy Procedures: A Systematic Review and Meta-Analysis.
PubMed 文献 · J Urol · 2024-09-30

该荟萃分析纳入8项研究共1374例患者,评估输尿管镜激光碎石术中反特伦德伦伯卧位(RevTren)或特伦德伦伯卧位(Tren)对比标准背侧截石位的效果。RevTren显著减少结石迁移(OR 0.20)、降低转换软镜需求(OR 0.28)并提高成功率(OR 2.90);Tren增加结石向肾上盏迁移(OR 2.12)并提高成功率(OR 3.56);并发症相当。

要点

  • RevTren显著减少输尿管结石迁移、降低转换软镜需求并提高成功率。
  • Tren增加输尿管及肾盏结石向肾上盏迁移并提高成功率。
  • 各体位并发症相当,两种体位均可安全用于临床实践。

核心结论

  • 调整输尿管镜激光碎石术中的患者体位可改善手术结局。
  • RevTren有效减少输尿管结石迁移和软镜使用需求,Tren促进输尿管及肾盏结石向肾上盏迁移并提高成功率。
  • 两种体位技术均较标准体位有显著优势,可安全用于临床实践而不影响患者安全。

研究设计与样本

  • 系统综述与荟萃分析,遵循PRISMA指南,检索MEDLINE、Embase、Scopus、Cochrane和Web of Science截至2024年3月。
  • 纳入8项研究,共1374例患者,评估输尿管镜碎石术中RevTren或Tren对比标准背侧截石位。

主要发现

  • RevTren显著减少输尿管结石迁移(OR 0.20;95%CI 0.08-0.47)。
  • RevTren降低转换软镜需求(OR 0.28;95%CI 0.12-0.67)。
  • RevTren提高成功率(OR 2.90;95%CI 1.88-4.48)。
  • Tren增加输尿管及肾盏结石向肾上盏迁移(OR 2.12;95%CI 1.48-3.04)。
  • Tren提高成功率(OR 3.56;95%CI 2.15-5.92),各体位并发症相当。

临床怎么用

  • 作者认为两种体位技术均可安全用于临床实践而不影响患者安全。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Urologists encounter multiple challenges in managing ureteral stones with ureteroscopic laser lithotripsy. This meta-analysis assesses the effectiveness of alternative surgical positioning, reverse Trendelenburg (RevTren) and Trendelenburg (Tren), in reducing stone migration and enhancing outcomes compared with standard dorsal lithotomy positioning. MATERIALS AND METHODS: A systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, searching MEDLINE, Embase, Scopus, Cochrane, and Web of Science up to March 2024. This review focused on studies evaluating RevTren or Tren positioning during ureteroscopic lithotripsy compared with standard dorsal lithotomy, analyzing end points such as stone migration, conversion rates, success rates, complications, and operative time. RESULTS: Of 137 studies identified, 8 met the inclusion criteria, encompassing 1374 patients. RevTren significantly reduced ureteral stone migration (odds ratio [OR], 0.20; 95% CI, 0.08-0.47), lowered the need for conversion to a flexible ureteroscope (OR, 0.28; 95% CI, 0.12-0.67), and improved success rates (OR, 2.90; 95% CI, 1.88-4.48). Tren increased migration of ureteral and calyceal stones toward upper renal calyces (OR, 2.12; 95% CI, 1.48-3.04) and achieved a higher success rate (OR, 3.56; 95% CI, 2.15-5.92). Complications were comparable across all positions. CONCLUSIONS: Adjusting patient positioning during ureteroscopic laser lithotripsy can enhance procedure outcomes. RevTren effectively reduces ureteral stone migration and the necessity for flexible ureteroscopes, whereas Tren facilitates ureteral and calyceal stone migration toward upper calyces, increasing success rates. Both positioning techniques offer significant advantages over standard positioning and can be safely adopted in clinical practice without compromising patient safety.

来源:J Urol,查看原文。版权归原作者所有。

引用

  1. Lepine HL, Vicentini FC, Molina WR, et al. Impact of Either Trendelenburg or Reverse Trendelenburg Positioning for Ureteroscopy Lithotripsy Procedures: A Systematic Review and Meta-Analysis. J Urol. 2024. PMID: 39348719. doi:10.1097/JU.0000000000004258

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。