输尿管镜及JJ支架置入后留置Foley导尿管:一项欧洲泌尿外科学会结石分会-青年学术泌尿外科医师(EULIS-YAU)随机前瞻性腔内泌尿外科研究
该随机前瞻性研究纳入112例单侧输尿管镜+JJ支架置入患者,1:1分为不留置Foley导尿管组(A组)与留置Foley导尿管组(B组)。两组术后生化指标、IPSS及USSQ各子项(除总身体疼痛评分外)相似,B组总身体疼痛评分较低;并发症均为Clavien-Dindo I-II级,A组发生率5.4%、B组8.9%。结论认为留置Foley导尿管对术后生化指标和排尿症状无显著影响,但可降低USSQ总身体疼痛评分,对VAS评分无显著影响。
要点
- 留置Foley导尿管对术后生化指标和排尿症状无显著影响。
- B组USSQ总身体疼痛评分低于A组,但VAS评分两组相似。
- 并发症均为Clavien-Dindo I-II级,A组5.4%、B组8.9%。
核心结论
- 输尿管镜+JJ支架置入后留置Foley导尿管对术后生化指标和排尿症状无显著影响。
- 留置Foley导尿管降低了USSQ总身体疼痛评分,但对VAS评分无显著影响。
- 输尿管镜+JJ支架置入后是否留置Foley导尿管应基于术者偏好,并考虑其对疼痛评分的潜在正面效应。
研究设计与样本
- 随机前瞻性临床试验(1:1),纳入成年单侧输尿管镜+JJ支架置入患者。
- A组不留置Foley导尿管,B组留置Foley导尿管。
- 共纳入112例患者,每组56例;所有患者均使用输尿管通路鞘。
主要发现
- 两组人口学和手术参数相似。
- 术前和术后生化分析包括白细胞计数、C反应蛋白、降钙素原和肌酐水平两组相似。
- 两组IPSS相似;USSQ除总身体疼痛评分外所有子项两组相似,总身体疼痛评分B组较低。
- VAS评分两组相似。
- 并发症均为Clavien-Dindo I-II级,并发症发生率A组5.4% vs B组8.9%。
临床怎么用
- 输尿管镜+JJ支架置入后是否留置Foley导尿管应基于术者偏好,并考虑其对疼痛评分的潜在正面效应。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate the effects of inserting a Foley catheter after ureteroscopy (URS) and JJ stent placement on pain scores, voiding patterns, biochemical parameters and postoperative complications. PATIENTS AND METHODS: A randomised clinical trial (1:1) with adult patients following unilateral URS + JJ stent placement was planned. In Group A, no Foley catheter was placed, in Group B, a Foley catheter was placed following URS + JJ stent placement. The primary objective was to evaluate effect of placing a Foley catheter on International Prostate Symptom Score (IPSS), Ureteric Stent Symptom Questionnaire (USSQ) score and postoperative biochemical parameters. The secondary objective was to evaluate postoperative complications. RESULTS: A total of 112 patients were included (56/group). A ureteric access sheath was used in each patient. Patients had similar demographic and surgical parameters. The pre- and postoperative biochemical analyses including white blood cell count, C-reactive protein, procalcitonin and creatinine levels were similar between the two groups. The IPSS were similar between the two groups. All the subdomains of the USSQ were similar between two groups except Total Body Pain score, which was lower in Group B. The visual analogue scale scores were similar. Complications were all Clavien-Dindo Grade I and II, and the complication rate was 5.4% and 8.9% in Group A and B, respectively. CONCLUSION: Placing a Foley catheter following URS + JJ stent placement did not show significant effects on postoperative biochemical parameters and voiding symptoms. However, a Foley catheter lowered the Total Body Pain score on the USSQ without having significant effects on VAS scores. The practice of placing a Foley catheter following URS and JJ stent placement should be based on surgeon's preference keeping in mind the potential positive effect on pain scores.
引用
- Sener TE, Ozgur G, Cetin M, et al. Foley catheter after ureteroscopy and JJ stent placement: a randomised prospective European Association of Urology Section of Urolithiasis-Young Academic Urologists (EULIS-YAU) endourology study. BJU Int. 2024. PMID: 39129326. doi:10.1111/bju.16504