本研究对DeepDx Prostate人工智能算法在前列腺根治标本全切片图像上进行Gleason分级的外部验证,使用来自第三家机构的150例根治标本制作的500个1-mm²组织块,以两位泌尿病理专家建立的国际泌尿病理学会分级分组为标准。AI与参考标准在区分癌与非癌组织及分级分组上均表现出高度一致性,尽管该算法此前仅用穿刺活检图像训练。

要点

  • DeepDx Prostate AI在根治标本组织块水平区分癌与非癌的敏感度为0.997、特异度为0.88。
  • AI与参考标准在分级分组分类上的二次加权Cohen kappa为0.89。
  • 两位专家在组织块水平确定分级分组的二次加权Cohen kappa为0.94。

核心结论

  • DeepDx Prostate AI算法与专家泌尿病理医师在前列腺根治标本的癌识别和分级上具有极好的一致性,尽管该算法是用来自完全不同患者群体的穿刺活检标本训练的。

研究设计与样本

  • 外部验证研究,使用来自第三家机构的150例前列腺根治标本制作的500个1-mm²组织块,评估市售DeepDx Prostate AI算法的Gleason模式输出。
  • 参考标准为两位经验丰富的泌尿病理专家依据国际泌尿病理学会分级分组确立的评级,分歧病例由第三位专家裁决。
  • 主要指标为与参考标准的一致性,采用Cohen kappa衡量。

主要发现

  • 两位经验丰富病理医师在组织块水平确定分级分组的一致性二次加权Cohen kappa为0.94。
  • AI算法与参考标准在区分癌与非癌组织的一致性未加权Cohen kappa为0.91。
  • AI算法与参考标准在将组织块分类为分级分组的一致性二次加权Cohen kappa为0.89。
  • AI算法区分癌与非癌组织的敏感度为0.997、特异度为0.88。
  • AI算法在分类GG≥2 vs GG1和非癌组织时敏感度为0.98、特异度为0.85。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To externally validate the performance of the DeepDx Prostate artificial intelligence (AI) algorithm (Deep Bio Inc., Seoul, South Korea) for Gleason grading on whole-mount prostate histopathology, considering potential variations observed when applying AI models trained on biopsy samples to radical prostatectomy (RP) specimens due to inherent differences in tissue representation and sample size. MATERIALS AND METHODS: The commercially available DeepDx Prostate AI algorithm is an automated Gleason grading system that was previously trained using 1133 prostate core biopsy images and validated on 700 biopsy images from two institutions. We assessed the AI algorithm's performance, which outputs Gleason patterns (3, 4, or 5), on 500 1-mm2 tiles created from 150 whole-mount RP specimens from a third institution. These patterns were then grouped into grade groups (GGs) for comparison with expert pathologist assessments. The reference standard was the International Society of Urological Pathology GG as established by two experienced uropathologists with a third expert to adjudicate discordant cases. We defined the main metric as the agreement with the reference standard, using Cohen's kappa. RESULTS: The agreement between the two experienced pathologists in determining GGs at the tile level had a quadratically weighted Cohen's kappa of 0.94. The agreement between the AI algorithm and the reference standard in differentiating cancerous vs non-cancerous tissue had an unweighted Cohen's kappa of 0.91. Additionally, the AI algorithm's agreement with the reference standard in classifying tiles into GGs had a quadratically weighted Cohen's kappa of 0.89. In distinguishing cancerous vs non-cancerous tissue, the AI algorithm achieved a sensitivity of 0.997 and specificity of 0.88; in classifying GG ≥2 vs GG 1 and non-cancerous tissue, it demonstrated a sensitivity of 0.98 and specificity of 0.85. CONCLUSION: The DeepDx Prostate AI algorithm had excellent agreement with expert uropathologists and performance in cancer identification and grading on RP specimens, despite being trained on biopsy specimens from an entirely different patient population.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Schmidt B, Soerensen SJC, Bhambhvani HP, et al. External validation of an artificial intelligence model for Gleason grading of prostate cancer on prostatectomy specimens. BJU Int. 2024. PMID: 38989669. doi:10.1111/bju.16464